<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href="http://www.blogger.com/styles/atom.css" type="text/css"?><feed xmlns='http://www.w3.org/2005/Atom' xmlns:openSearch='http://a9.com/-/spec/opensearchrss/1.0/' xmlns:georss='http://www.georss.org/georss'><id>tag:blogger.com,1999:blog-6953549091784501422</id><updated>2009-12-18T01:34:08.431-08:00</updated><title type='text'>NMR Analysis, Processing and Prediction</title><subtitle type='html'></subtitle><link rel='http://schemas.google.com/g/2005#feed' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/posts/default'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default?orderby=updated'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/'/><link rel='hub' href='http://pubsubhubbub.appspot.com/'/><link rel='next' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default?start-index=26&amp;max-results=25&amp;orderby=updated'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email></author><generator version='7.00' uri='http://www.blogger.com'>Blogger</generator><openSearch:totalResults>56</openSearch:totalResults><openSearch:startIndex>1</openSearch:startIndex><openSearch:itemsPerPage>25</openSearch:itemsPerPage><entry><id>tag:blogger.com,1999:blog-6953549091784501422.post-2617683664157066719</id><published>2009-11-30T08:01:00.000-08:00</published><updated>2009-12-01T00:29:58.834-08:00</updated><title type='text'>Basis on qNMR: Integration Rudiments (Part I)</title><content type='html'>First a quick recap. In my &lt;a href="http://nmr-analysis.blogspot.com/2009/11/basis-on-qnmr-intramolecular-vs.html"&gt;last post I put forward the idea that integration of NMR peaks is the basis of quantitative analysis.&lt;/a&gt; Before going any further, I would like to mention that, alternatively, peak heights can also be used for quantitation, but unless some special pre-processing is employed (see for example P. A. Haysa, R. A. Thompson, &lt;span style="font-style: italic;"&gt;Magn. Reson. Chem&lt;/span&gt;., &lt;span style="font-weight: bold;"&gt;2009&lt;/span&gt;, 47, 819 – 824, &lt;a href="http://doi.wiley.com/10.1002/mrc.2464"&gt;doi&lt;/a&gt;) measurement of peak areas is generally the recommended method for qNMR assays.&lt;br /&gt;&lt;div style="text-align: justify;"&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;In this post I will cover some very basic rudiments of NMR peak areas measurements, without going into depth into complicated math , as my objective is just to set the basis for oncoming, more advanced posts.&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;&lt;span style="font-weight: bold;font-size:130%;" &gt;NMR Integration basic Rudiments&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;Peak areas may be determined in various ways. While I was still at school I learnt a very simple peak area calculation method which just required a good analytical balance and scissors. This was the so-called ‘cut &amp;amp; weigh method’ and is illustrated in the figure below.&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_-MfflvAgRls/SxP4p1lbphI/AAAAAAAAAg8/U8Q3u6S3PSE/s1600/cutweigh.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 337px;" src="http://4.bp.blogspot.com/_-MfflvAgRls/SxP4p1lbphI/AAAAAAAAAg8/U8Q3u6S3PSE/s400/cutweigh.jpg" alt="" id="BLOGGER_PHOTO_ID_5409940975044503058" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;By simply cutting out a rectangle of known value, for example, known ppm or Hz on x-axis and known intensities on the y-axis, a calibration standard is obtained (in this case, 8 units of area). After cutting and weighing this standard, the area of any peak can be determined by cutting and weighing the peak(s) from the chart, weighing the paper and using this equation:&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;&lt;code&gt;Area of Peak(s) = Area of standard * Weight of peak / Weight of standard&lt;/code&gt;&lt;br /&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;Yet, despite its primitiveness, this technique was remarkably precise for the purpose for which it was intended (obviously, not for accurate NMR peak areas measurement :-) ) but, of course, it assumed that the density of the paper was homogenous.&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;There are other classical methods such as counting squares, &lt;a href="http://en.wikipedia.org/wiki/Planimeter"&gt;planimeters&lt;/a&gt;  or mechanical integrators but in general they were  subject to large errors. In the analogic era, it was more convenient to measure the integral as a function of time, using an electronic integrator to sum the output voltage of the detector over the time of passage through the signals. In those old days, as described in [2], before the FT NMR epoch, the plotter was set to integral mode and the pen was swept through the peak or group of peaks as the pen level rose with the integrated intensity.&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;Enough about archaic methods, we are in the 21st century now and all NMR spectra are digitalized, processed and analyzed by computers.  As Richard Ernst wrote once [1], &lt;span style="font-style: italic;"&gt;Without Computers – no modern NMR&lt;/span&gt;.  How are NMR integrals measured? From a user point of view, it’s very straightforward: the user selects the left and right limits of the peaks to be integrated and the software reports the area (most NMR software packages have automated routines to automatically select the spectral segments to be integrated). For example, the figure below shows how this is done with our NMR software, &lt;a href="http://mestrelab.com/Products/Mnova-NMR/Details.html"&gt;Mnova&lt;/a&gt;.&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_-MfflvAgRls/SxP4qkfjGvI/AAAAAAAAAhU/RSb2EsBS1_E/s1600/integrationMnova.png"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 271px;" src="http://3.bp.blogspot.com/_-MfflvAgRls/SxP4qkfjGvI/AAAAAAAAAhU/RSb2EsBS1_E/s400/integrationMnova.png" alt="" id="BLOGGER_PHOTO_ID_5409940987636292338" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-weight: bold;font-size:130%;" &gt;Integration: What’s under the hood&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;But the question is: how is the computer actually calculating NMR peak areas?  In order to answer this, let’s revisit some very simple integration concepts.&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;From basic calculus we all learnt in school, we know that in order to compute the area of a function (e.g. f(x)) we simply need to calculate the integral of that function over a given interval (e.g. [a,b]).&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_-MfflvAgRls/SxP-CkWXX1I/AAAAAAAAAiE/QlhFAQs-AE4/s1600/ScreenShot001.gif"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 99px; height: 58px;" src="http://3.bp.blogspot.com/_-MfflvAgRls/SxP-CkWXX1I/AAAAAAAAAiE/QlhFAQs-AE4/s400/ScreenShot001.gif" alt="" id="BLOGGER_PHOTO_ID_5409946897472773970" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;If the function to be integrated (integrand) f(x) is known, we can analytically calculate the value of the area. For example, if the function has the simple quadratic expression&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_-MfflvAgRls/SxP-C-gHTcI/AAAAAAAAAiM/GgPOEdaLFBM/s1600/ScreenShot002.gif"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 73px; height: 24px;" src="http://4.bp.blogspot.com/_-MfflvAgRls/SxP-C-gHTcI/AAAAAAAAAiM/GgPOEdaLFBM/s400/ScreenShot002.gif" alt="" id="BLOGGER_PHOTO_ID_5409946904492985794" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;and we want to calculate the area under the curve over the interval [1,3], we just need to apply the well known Fundamental Theorem of Calculus so that the resulting area will be:&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_-MfflvAgRls/SxP-DLGjAEI/AAAAAAAAAiU/6zZevlrXBD8/s1600/ScreenShot003.gif"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 271px; height: 58px;" src="http://1.bp.blogspot.com/_-MfflvAgRls/SxP-DLGjAEI/AAAAAAAAAiU/6zZevlrXBD8/s400/ScreenShot003.gif" alt="" id="BLOGGER_PHOTO_ID_5409946907875409986" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_-MfflvAgRls/SxP47QhFsSI/AAAAAAAAAh0/QV_CsWhruyE/s1600/x2.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 253px;" src="http://4.bp.blogspot.com/_-MfflvAgRls/SxP47QhFsSI/AAAAAAAAAh0/QV_CsWhruyE/s400/x2.jpg" alt="" id="BLOGGER_PHOTO_ID_5409941274331820322" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;Unfortunately, real life is always more complex. Where NMR is concerned, function f(x) is, in general, not known so it cannot be integrated as done before using the Calculus fundamental theorem. I wrote ‘in general’ because theory tells us the analytical expression for an NMR signal (i.e. we know that, at a good approximation, NMR signals can be modeled as Lorentzian functions) but, for the moment, let’s consider the more general case in which the NMR signal has an unknown lineshape.&lt;br /&gt;&lt;br /&gt;Furthermore, up until now we have assumed that f(x) is a continuous function. Obviously, this is not the case for computer generated NMR signals as they are discrete points as a result of the analog to digital conversion. Basically, the digitizer in the spectrometer samples the FID voltage, usually at regular time intervals and assigns a number to the intensity. As a result, a tabulated list of numbers is stored in the computer. This is the so-called FID which, after a discrete Fourier Transform yields the frequency domain spectrum. So how can a tabular set of data points (the discrete spectrum) can be integrated?&lt;br /&gt;&lt;br /&gt;A very naive method (yet as we will see shortly, very efficient) is to use very simple approximations for the area: Basically the integral is approximated by dividing the area into thin vertical blocks, as shown in the image below.&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_-MfflvAgRls/SxQGmKPKChI/AAAAAAAAAjM/TWitpBRi4nU/s1600/IntegralSums1.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 329px;" src="http://1.bp.blogspot.com/_-MfflvAgRls/SxQGmKPKChI/AAAAAAAAAjM/TWitpBRi4nU/s400/IntegralSums1.jpg" alt="" id="BLOGGER_PHOTO_ID_5409956305031531026" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_-MfflvAgRls/SxP5tKYcyPI/AAAAAAAAAh8/lfsvUUh4AFY/s1600/Riemann.jpg"&gt;&lt;img style="margin: 0pt 0pt 10px 10px; float: right; cursor: pointer; width: 142px; height: 200px;" src="http://2.bp.blogspot.com/_-MfflvAgRls/SxP5tKYcyPI/AAAAAAAAAh8/lfsvUUh4AFY/s200/Riemann.jpg" alt="" id="BLOGGER_PHOTO_ID_5409942131678431474" border="0" /&gt;&lt;/a&gt;This method is called the &lt;a href="http://en.wikipedia.org/wiki/Riemann_integral"&gt;Riemann Integra&lt;/a&gt;l after its inventor, &lt;a href="http://en.wikipedia.org/wiki/Bernhard_Riemann"&gt;Bernhard Riemann&lt;/a&gt;.&lt;br /&gt;&lt;div style="text-align: left;"&gt;&lt;br /&gt;&lt;/div&gt;Intuitively we can observe that the approximation gets better if we increase the number of rectangles (more on this in a moment). In practice, the number of rectangles is defined by the number of discrete points (digital resolution) in such a way that every point in the region of the spectrum to be integrated defines a rectangle.&lt;br /&gt;&lt;br /&gt;For example, let’s consider the NMR peak shown in the figure below which I simulated using the spin simulation module of Mnova. It consists of a single Lorentzian peak with a line width at half height of 0.8531 points and a height of 100. With all this information we can know in advance the expected exact area calculated as follows:&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_-MfflvAgRls/SxP-DttxonI/AAAAAAAAAic/l3fZo_EBLbE/s1600/ScreenShot004.gif"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 18px;" src="http://1.bp.blogspot.com/_-MfflvAgRls/SxP-DttxonI/AAAAAAAAAic/l3fZo_EBLbE/s400/ScreenShot004.gif" alt="" id="BLOGGER_PHOTO_ID_5409946917166752370" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;In the spectrum shown in the image below we can see the individual digital points as crosses and the continuous trace which have been constructed by connecting the crosses by straight lines (usually only these lines are shown in most NMR software packages. The capability of showing both the discrete points and the continuous curve is a special feature of &lt;a href="http://mestrelab.com/Products/Mnova-NMR/Details.html"&gt;Mnova&lt;/a&gt;.&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_-MfflvAgRls/SxP462bQuxI/AAAAAAAAAhk/R342l3bJvjk/s1600/SpectrumIntegral1.png"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 280px;" src="http://1.bp.blogspot.com/_-MfflvAgRls/SxP462bQuxI/AAAAAAAAAhk/R342l3bJvjk/s400/SpectrumIntegral1.png" alt="" id="BLOGGER_PHOTO_ID_5409941267328056082" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;If the simple Riemann method is applied, we obtain an area = 146, which represents an error of ca 21% with respect to the true area value (184.12). It’s worth mentioning that the true value is calculated by integrating the function from minus infinite to plus infinite whilst in the example above the integration interval is very narrow.&lt;br /&gt;&lt;br /&gt;As mentioned above, the approximate area should get better if we increase the number of rectangles. This is very easy to achieve if we use some kind of interpolation to, for example, double the number of discrete points. We could use some basic linear interpolation directly in the frequency domain, although in NMR we know that a better approach is to extend the FID with zeroes via the so-called zero filling operation.&lt;br /&gt;&lt;br /&gt;So if we double the number of digital points and thus the number of rectangles used for the area calculation we obtain a value of 258 (see image below). In this case, as the digital resolution is higher, the line width at half height is also higher, 1.7146 (in other words, we have more digital points per peak) so the true integral value will be 269.32:&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_-MfflvAgRls/SxP-DuaTxHI/AAAAAAAAAik/Zbr-Gt_qYnE/s1600/ScreenShot005.gif"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 17px;" src="http://3.bp.blogspot.com/_-MfflvAgRls/SxP-DuaTxHI/AAAAAAAAAik/Zbr-Gt_qYnE/s400/ScreenShot005.gif" alt="" id="BLOGGER_PHOTO_ID_5409946917353538674" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_-MfflvAgRls/SxP47MpHKxI/AAAAAAAAAhs/WhNbdnEgh1Q/s1600/SpectrumIntegral2.png"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 279px;" src="http://1.bp.blogspot.com/_-MfflvAgRls/SxP47MpHKxI/AAAAAAAAAhs/WhNbdnEgh1Q/s400/SpectrumIntegral2.png" alt="" id="BLOGGER_PHOTO_ID_5409941273291729682" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;Now the error we are committing is just as little as 4%.  As a general rule it can be said that the better the digital resolution, the better the integration accuracy.&lt;br /&gt;&lt;br /&gt;Mathematically, Riemann method can be formulated as:&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_-MfflvAgRls/SxP-kt7vBlI/AAAAAAAAAis/sWcCZJze6Rg/s1600/ScreenShot006.gif"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 152px; height: 27px;" src="http://3.bp.blogspot.com/_-MfflvAgRls/SxP-kt7vBlI/AAAAAAAAAis/sWcCZJze6Rg/s400/ScreenShot006.gif" alt="" id="BLOGGER_PHOTO_ID_5409947484160984658" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;Considering that in almost all NMR experiments, we are interested in relative  areas, the spacing between data points, &lt;em&gt;Δx&lt;/em&gt; , is a common factor and can be dropped from the formulas with no loss of generality.&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_-MfflvAgRls/SxP-k2HyGFI/AAAAAAAAAi0/8B9tMeGh9M4/s1600/ScreenShot007.gif"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 137px; height: 30px;" src="http://3.bp.blogspot.com/_-MfflvAgRls/SxP-k2HyGFI/AAAAAAAAAi0/8B9tMeGh9M4/s400/ScreenShot007.gif" alt="" id="BLOGGER_PHOTO_ID_5409947486359001170" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;This is exactly the method of choice of most NMR software packages for peak area calculations: NMR integrals are calculated by determining the running sum of all points in the integration segment.&lt;br /&gt;&lt;br /&gt;&lt;span style="font-weight: bold;font-size:130%;" &gt;Other numeric integration methods&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;One important conclusion from the previous section is that in order to get more accurate areas we should increase the number of integration rectangles, something which is equivalent to increasing the number of digital points (e.g. by acquiring more points or using zero filling).&lt;br /&gt;&lt;br /&gt;Instead of using the running sum of the simple individual rectangles, we can use some kind of polynomial interpolation between the limits defining each rectangle. The simplest method uses linear interpolation so that instead of rectangles we use trapezoids. This is the well known trapezoid rule which is formulated as:&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_-MfflvAgRls/SxQOZ4ueVNI/AAAAAAAAAjc/-b3dbcwVUhw/s1600/ScreenShot008.gif"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 374px; height: 45px;" src="http://4.bp.blogspot.com/_-MfflvAgRls/SxQOZ4ueVNI/AAAAAAAAAjc/-b3dbcwVUhw/s400/ScreenShot008.gif" alt="" id="BLOGGER_PHOTO_ID_5409964890265638098" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;If instead of linear interpolation we use parabolic interpolation, the method receives the name of Simpson as it’s formulated as [3]:&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_-MfflvAgRls/SxP-lZvmvGI/AAAAAAAAAjE/euPSishDMdM/s1600/ScreenShot009.gif"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 21px;" src="http://1.bp.blogspot.com/_-MfflvAgRls/SxP-lZvmvGI/AAAAAAAAAjE/euPSishDMdM/s400/ScreenShot009.gif" alt="" id="BLOGGER_PHOTO_ID_5409947495921269858" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;It is limited to situations where there are an even number of segments and thus, odd number of points. These 3 methods are summarized graphically in the figure below.&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_-MfflvAgRls/SxQGwPEXCSI/AAAAAAAAAjU/PFwy0YfwqTU/s1600/IntegralMethods.png"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 121px;" src="http://2.bp.blogspot.com/_-MfflvAgRls/SxQGwPEXCSI/AAAAAAAAAjU/PFwy0YfwqTU/s400/IntegralMethods.png" alt="" id="BLOGGER_PHOTO_ID_5409956478127114530" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;Other more sophisticated methods such as Romberg, Gaussian quadrature, etc, are beyond the scope of this post and &lt;a href="http://en.wikipedia.org/wiki/Numerical_integration"&gt;can be found elsewhere&lt;/a&gt;.&lt;br /&gt;&lt;br /&gt;&lt;span style="font-weight: bold;font-size:130%;" &gt;Which integration method is more suitable for NMR?&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;This question will remain unanswered for now, open for discussion.  Of the 3 integration methods discussed in this post, at first glance Simpson should be the most accurate. However, as explained in [3], this method is more sensitive to the integral limits (e.g. left and right boundaries) in such a way that if the limits are shifted one point to the left or to the right, the integral value will change significantly, while the other two approaches are more robust and the values are less affected.&lt;br /&gt;&lt;br /&gt;In my experience, the difference between the simple sum and trapezoid method is small compared to other sources of errors (e.g. systematic and random errors, to be discussed in my next post) so using one approach or the other should not make any relevant difference.&lt;br /&gt;&lt;br /&gt;Naturally, if very precise integral values are required, then more advanced methods based on deconvolution should be used. Of course, if you have any input, you’re more than welcome to leave your comments here.&lt;br /&gt;&lt;br /&gt;&lt;span style="font-weight: bold;font-size:130%;" &gt;Conclusions&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;There's a great deal more to NMR Integrals than reviewed here: I have simply scratched the surface. In my next post, I will follow up with the limits and drawbacks of standard NMR integration, introducing better approaches such as Line Fitting or Deconvolution.&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;hr style="margin-left: 0px; margin-right: 0px;"&gt;&lt;div style="text-align: justify;"&gt;&lt;br /&gt;&lt;span style="font-weight: bold;font-size:130%;" &gt;References&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;[1] Ernst Richard R., Without computers - no modern NMR, in Computational Aspects of the Study of Biological Macromolecules by Nuclear Magnetic Resonance Spectroscopy, Edited by J.C.Hoch et al. Plenum Press 1991, pages 1-25&lt;br /&gt;&lt;br /&gt;[2] Neil E. Jacobsen, NMR Spectroscopy Explained: Simplified Theory, Applications and Examples for Organic Chemistry and Structural Biology, N.J. : Wiley-Interscience, 2007&lt;br /&gt;&lt;br /&gt;[3] Jeffrey C. Hoch and Alan S. Stern, NMR Data Processing, Wiley-Liss, New York (1996)&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6953549091784501422-2617683664157066719?l=nmr-analysis.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/2617683664157066719/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='https://www.blogger.com/comment.g?blogID=6953549091784501422&amp;postID=2617683664157066719' title='1 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/2617683664157066719'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/2617683664157066719'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/2009/11/basis-on-qnmr-integration-rudiments.html' title='Basis on qNMR: Integration Rudiments (Part I)'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email><gd:extendedProperty xmlns:gd='http://schemas.google.com/g/2005' name='OpenSocialUserId' value='16047913759663550274'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/_-MfflvAgRls/SxP4p1lbphI/AAAAAAAAAg8/U8Q3u6S3PSE/s72-c/cutweigh.jpg' height='72' width='72'/><thr:total xmlns:thr='http://purl.org/syndication/thread/1.0'>1</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6953549091784501422.post-2468836096203107457</id><published>2009-11-22T10:07:00.000-08:00</published><updated>2009-11-22T15:08:54.634-08:00</updated><title type='text'>Basis on qNMR: Intramolecular vs Mixtures qNMR</title><content type='html'>&lt;span style="font-size:130%;"&gt;&lt;span style="font-weight: bold;"&gt;&lt;br /&gt;A bit of historical background&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;NMR has won its reputation as a powerful tool for structure determination of organic molecules. In addition to the information provided by chemical shifts and coupling constants, the quantitative relationships existing between the peaks (or groups of peaks - multiplets) arising from the various nuclides in the sample has proven pivotal for the assignment and interpretation of NMR spectra.&lt;br /&gt;&lt;br /&gt;Despite the fact that the concept of quantitative NMR (qNMR) has been coupled to NMR since the early 1950, shortly after the technique's inception, it seems as NMR, as an analytical tool for quantitative analysis was firstly mentioned in 1963 by Jungnickel and Forbes [&lt;a href="http://pubs.acs.org/doi/abs/10.1021/ac60201a005"&gt;Anal. Chem., 1963, 35 (8), pp 938–942&lt;/a&gt;] who determined the intramolecular proton ratios in 26 pure organic substances and Hollis [&lt;a href="http://pubs.acs.org/doi/abs/10.1021/ac60204a043"&gt;Anal. Chem., 1963, 35 (11), pp 1682–1684&lt;/a&gt;] who analyzed the amount fractions of aspirin, phenacetine and caffeine in respective mixtures.&lt;br /&gt;&lt;br /&gt;From those pioneer works, many and varied studies on qNMR arose. As pointed out in &lt;a href="http://pubs.acs.org/doi/abs/10.1021/jf0114379"&gt;J. Agric. Food Chem. 2002, 50, 3366-3374&lt;/a&gt;, &lt;span style="font-weight: bold;"&gt;qNMR &lt;/span&gt;is particularly suitable for the simultaneous determination of the percentage of active compounds and impurities in organic chemicals such as pharmaceuticals, agrochemicals and natural products, as well as vegetable oils, fuels and solvents, process monitoring, determination of enantiomeric excess, etc.&lt;br /&gt;&lt;br /&gt;In what follows, I will use the term qNMR to refer to any quantitative measurement of NMR signals, regardless of whether the technique is employed as an analytical method  (e.g. determination of the relative amounts of the components in a mixture) or as tool for structure determination or conformational analysis.&lt;br /&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;&lt;span style="font-weight: bold;"&gt;What’s the deal with qNMR?&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;The basic principle of qNMR assays is that, ideally, the integral of the set of all peaks which can be assigned to a particular nucleus is proportional to the molar concentration of that nucleus in the sample. Theoretically, this holds quite well, though there are deviations from the rule in strongly coupled systems. An important point to keep in mind is the word “ideally”; this includes, for example, perfectly relaxed samples.&lt;br /&gt;Even so there remain a number of problems which can be first of all divided into two categories:&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;ol&gt;&lt;li&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;Sources of statistical assessment errors (scatter)&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;Sources of systematic assessment deviations (bias)&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;&lt;/ol&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;I will cover these points in detail in separate posts.&lt;br /&gt;&lt;br /&gt;&lt;span style="font-weight: bold;font-size:130%;" &gt;Intramolecular vs Intermolecular (mixtures) qNMR&lt;/span&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;The most important fundamental concept of qNMR is based on the fact that, the absorption coefficient for the absorption of electromagnetic energy is the same for all nuclides of the same species, regardless whether they belong to one or several molecules (e.g mixture). As a result, the NMR signal response (more precisely the integrated signal area) is directly proportional to the number of nuclides contributing to the signal.&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;For example, all organic chemists are very familiar with integrating the multiples of a 1H spectrum to elucidate or confirm a particular molecular structure (see figure below)&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_-MfflvAgRls/Swl_A3GIBfI/AAAAAAAAAg0/2KK-KVPvUJI/s1600/Integral.jpeg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 229px;" src="http://3.bp.blogspot.com/_-MfflvAgRls/Swl_A3GIBfI/AAAAAAAAAg0/2KK-KVPvUJI/s400/Integral.jpeg" alt="" id="BLOGGER_PHOTO_ID_5406992480401360370" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;This application can be classified as &lt;span style="font-weight: bold; font-style: italic;"&gt;Intramolecular qNMR&lt;/span&gt;. NOE spectra, where the intensity is related to the distance between spins and represents the main basis for NMR as a tool in structural molecular biology, is another application of Intramolecular qNMR (Note: In this context I’m not including Transfer-NOE used e.g. to study the structure of a ligand in a complex under conditions of fast exchange)&lt;br /&gt;&lt;br /&gt;Let’s consider now another example, &lt;span style="font-weight: bold; font-style: italic;"&gt;Intermolecular qNMR&lt;/span&gt;:&lt;br /&gt;Purity determination of a compound using an internal standard (is) with known purity and assuming instrumental parameters properly set is given by the equation below (see for example, &lt;a href="http://doi.wiley.com/10.1002/mrc.2464"&gt;10.1002/mrc.2464&lt;/a&gt;):&lt;br /&gt;&lt;br /&gt;% purity by weight = W(is)/W(s) * A(s)/A(is)*MW(s)/MW(is)*H(is)/H(s)&lt;br /&gt;&lt;br /&gt;where W(s) and W(is) are the weights of the sample and ISTD, A(s) and A(is) are the integrals (areas) of the sample and ISTD peaks, MW(s) and MW(is) are the molecular weights of the sample and ISTD, and H(s) and H(is) are the number of hydrogens represented by the integral for the sample and ISTD, respectively.&lt;br /&gt;&lt;br /&gt;As a simple application, see &lt;a href="http://www.asdlib.org/onlineArticles/ecourseware/Larive/Q-NMR%20for%20purity%20determination%20of%20macrolide%20antibiotic%20reference%20standards.pdf"&gt;Q-NMR for purity determination of macrolide antibiotic reference standards: Comparison with the mass balance method&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;Common to all qNMR studies is the calculation of NMR integrals. In my next post, I will cover the &lt;span style="font-weight: bold;"&gt;basic principles on NMR integration&lt;/span&gt;. &lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6953549091784501422-2468836096203107457?l=nmr-analysis.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/2468836096203107457/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='https://www.blogger.com/comment.g?blogID=6953549091784501422&amp;postID=2468836096203107457' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/2468836096203107457'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/2468836096203107457'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/2009/11/basis-on-qnmr-intramolecular-vs.html' title='Basis on qNMR: Intramolecular vs Mixtures qNMR'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email><gd:extendedProperty xmlns:gd='http://schemas.google.com/g/2005' name='OpenSocialUserId' value='16047913759663550274'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_-MfflvAgRls/Swl_A3GIBfI/AAAAAAAAAg0/2KK-KVPvUJI/s72-c/Integral.jpeg' height='72' width='72'/><thr:total xmlns:thr='http://purl.org/syndication/thread/1.0'>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6953549091784501422.post-1645795059010321178</id><published>2009-11-21T09:58:00.000-08:00</published><updated>2009-11-21T10:28:11.346-08:00</updated><title type='text'>Basis on qNMR: Rudiments</title><content type='html'>&lt;div style="text-align: justify;"&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_-MfflvAgRls/SwgqmEW0Y2I/AAAAAAAAAgs/kvnVoDo_Cms/s1600/Intro1.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 370px; height: 320px;" src="http://3.bp.blogspot.com/_-MfflvAgRls/SwgqmEW0Y2I/AAAAAAAAAgs/kvnVoDo_Cms/s400/Intro1.jpg" alt="" id="BLOGGER_PHOTO_ID_5406618186151125858" border="0" /&gt;&lt;/a&gt;When I started playing drums, so man&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;y years ago, I kept hearing about so-called "&lt;span style="font-style: italic;"&gt;Drum Rudiments&lt;/span&gt;". By that time, I was too young to realize how important they were and to me, they appear just as boring and repetitive exercises. However, rudiments (basic building blocks or "vocabulary" of drumming) are absolutely essential to master drums (something I have to admit I never achieved :-) ) &lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;In the last few years I’ve had the opportunity to meet and interact with many chemists who are using our &lt;a href="http://www.mestrelab.com/"&gt;NMR software&lt;/a&gt;. Some of them are NMR specialists with an outstanding knowledge from whom I have learnt a lot. On the other hand, other chemists use NMR on daily basis simply to confirm the structure(s) they have just synthesized but do not have a deep grasp of the inner details of NMR theory and signal data processing. Whilst I understand that in general this is fine, I have noticed recently that many of these less-experienced NMR scientists are now getting involved in more advanced NMR studies and, in my humble opinion, the lack of some important rudiments can lead to an improper interpretation of the NMR data. &lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;One interesting example is quantitative NMR (qNMR), a field which is being used increasingly in the pharmaceutical industry, for instance, to quantify impurity levels, but it’s also very important in the field of natural products (see for example &lt;a href="http://pubs.acs.org/doi/abs/10.1021/np060535r"&gt;J. Nat. Prod. 2007, 70, 589-595&lt;/a&gt;) and for the calibration of other quantitative techniques such as HPLC. Typically, qNMR is based on obtaining quantitative information through integral-based calculations so in principle, it might seem as this is something trivial which does not require any additional effort. Whilst this is generally true, there are some very important rudiments which I think are worth pointing out.&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;The rudiments I will present in this series of articles will range from basic concepts on NMR Integration to more advanced deconvolution techniques, including our newly developed Global Spectral Deconvolution algorithm, &lt;a href="http://nmr-analysis.blogspot.com/2009/06/fighting-against-peak-overlap.html"&gt;GSD&lt;/a&gt;.&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;So if you have any interest in qNMR, watch this space. I promise to post these qNMR rudiments on a regular basis.&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-family:arial;"&gt;&lt;span style="font-size:100%;"&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6953549091784501422-1645795059010321178?l=nmr-analysis.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/1645795059010321178/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='https://www.blogger.com/comment.g?blogID=6953549091784501422&amp;postID=1645795059010321178' title='3 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/1645795059010321178'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/1645795059010321178'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/2009/11/basis-on-qnmr-rudiments.html' title='Basis on qNMR: Rudiments'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email><gd:extendedProperty xmlns:gd='http://schemas.google.com/g/2005' name='OpenSocialUserId' value='16047913759663550274'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_-MfflvAgRls/SwgqmEW0Y2I/AAAAAAAAAgs/kvnVoDo_Cms/s72-c/Intro1.jpg' height='72' width='72'/><thr:total xmlns:thr='http://purl.org/syndication/thread/1.0'>3</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6953549091784501422.post-2553975493776655145</id><published>2009-11-19T02:33:00.000-08:00</published><updated>2009-11-19T02:38:04.763-08:00</updated><title type='text'>Micropost [OT]: NMR meets Football</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_-MfflvAgRls/SwUfZ413_FI/AAAAAAAAAgk/SY9PjMIRoDQ/s1600/NMRBalls.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 245px;" src="http://2.bp.blogspot.com/_-MfflvAgRls/SwUfZ413_FI/AAAAAAAAAgk/SY9PjMIRoDQ/s400/NMRBalls.jpg" alt="" id="BLOGGER_PHOTO_ID_5405761457343691858" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-family:arial;"&gt;&lt;span style="font-size:100%;"&gt;Relaxation plays a major role in NMR spectroscopy – What’s better than playing sports to chill out and forget about everyday problems?&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;/div&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-family:arial;"&gt;&lt;span style="font-size:100%;"&gt;I reckon &lt;a href="http://mestrec.com/blog/index.php/2009/11/mestrelab-world-of-sports-free-mnova-t-shirt-quiz/"&gt;this&lt;/a&gt; is not the best football team you might find but at least I guarantee they are fun people (sponsored by a great company :-) ) with whom you can have a good time (and get a &lt;a href="http://mestrec.com/blog/index.php/2009/11/mestrelab-world-of-sports-free-mnova-t-shirt-quiz/"&gt;free t-shirt!&lt;/a&gt;) :-)&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;/div&gt;&lt;span style="font-family:arial;"&gt;&lt;span style="font-size:100%;"&gt;&lt;br /&gt;&lt;a href="http://mestrec.com/blog/index.php/2009/11/mestrelab-world-of-sports-free-mnova-t-shirt-quiz/"&gt;Mestrelab World of Sports - Free Mnova t-shirt quiz&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6953549091784501422-2553975493776655145?l=nmr-analysis.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/2553975493776655145/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='https://www.blogger.com/comment.g?blogID=6953549091784501422&amp;postID=2553975493776655145' title='2 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/2553975493776655145'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/2553975493776655145'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/2009/11/micropost-ot-nmr-meets-football.html' title='Micropost [OT]: NMR meets Football'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email><gd:extendedProperty xmlns:gd='http://schemas.google.com/g/2005' name='OpenSocialUserId' value='16047913759663550274'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_-MfflvAgRls/SwUfZ413_FI/AAAAAAAAAgk/SY9PjMIRoDQ/s72-c/NMRBalls.jpg' height='72' width='72'/><thr:total xmlns:thr='http://purl.org/syndication/thread/1.0'>2</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6953549091784501422.post-1714456424375322566</id><published>2009-11-03T06:49:00.000-08:00</published><updated>2009-11-03T07:22:34.354-08:00</updated><title type='text'>Windows 7</title><content type='html'>&lt;div style="text-align: justify;"&gt;&lt;span style="font-family:arial;"&gt;&lt;span style="font-size:100%;"&gt;Windows 7 was released last week marking, in the opinion of many analysts, the beginning of the end of Windows Vista. Microsoft expects that Windows 7 will woo users who have resisted Vista by offering higher performance and compatibility as well as extra features. In fact, Windows 7 has been the &lt;a href="http://mashable.com/2009/10/21/windows-7-bigger-harry-potter/"&gt;biggest pre-order item&lt;/a&gt; in the history of Amazon UK.&lt;br /&gt;If you are interested in making the switch, our preliminary tests indicate that Mnova 6.0.2 runs smoothly under Windows 7. Either way, we cannot exclude any incompatibility as our tests on Windows 7 have not been as comprehensive as we would have liked (still working on it though).&lt;br /&gt;&lt;br /&gt;So if you are running Windows 7 and find any problem with Mnova, we would really appreciate it if you could let us know&lt;br /&gt;&lt;br /&gt;&lt;span style="font-style: italic;"&gt;NOTE: Some users have reported problems with version 5.2.5 Lite on Windows 7, although we have not been able to reproduce them in our computers. Rest assured that we are currently investigating this further &lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6953549091784501422-1714456424375322566?l=nmr-analysis.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/1714456424375322566/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='https://www.blogger.com/comment.g?blogID=6953549091784501422&amp;postID=1714456424375322566' title='2 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/1714456424375322566'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/1714456424375322566'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/2009/11/windows-7.html' title='Windows 7'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email><gd:extendedProperty xmlns:gd='http://schemas.google.com/g/2005' name='OpenSocialUserId' value='16047913759663550274'/></author><thr:total xmlns:thr='http://purl.org/syndication/thread/1.0'>2</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6953549091784501422.post-6856420964138923328</id><published>2009-10-21T16:07:00.000-07:00</published><updated>2009-10-21T16:11:44.940-07:00</updated><title type='text'>Binning and NMR Data Analysis</title><content type='html'>&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;Yesterday I mentioned that many NMR arrayed experiments suffer from unwanted chemical shift variations due to fluctuations in experimental conditions such as sample temperature, pH, ionic strength, etc. This phenomenon is very common in NMR spectra of e.g. biofluids (metabonomics/metabolomics) but also exists in many other experiments such us Relaxation, Kinetics and PFG NMR spectra (diffusion).&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;/div&gt;&lt;div style="text-align: justify;"&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;This problem negatively affects the reliability of quantitation using, for instance, peak heights, and for this reason integration is, in general, a more robust procedure as these spectral variations are mitigated by averaging data points over the integral segment. In this post, I just want to show you one simple trick which helps to understand, in a pictorial way, why integration is useful to remove the major part of chemical shift scattering.&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;/div&gt;&lt;/div&gt;&lt;div style="text-align: justify;"&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;First, consider the following experiment depicted in the figure below. It shows a triplet and as you can see, some minor peaks shifts are present from spectrum to spectrum&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_-MfflvAgRls/St-UoKIhucI/AAAAAAAAAgM/Tzp-FliKYd8/s1600-h/Misalignment.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 279px;" src="http://3.bp.blogspot.com/_-MfflvAgRls/St-UoKIhucI/AAAAAAAAAgM/Tzp-FliKYd8/s400/Misalignment.jpg" alt="" id="BLOGGER_PHOTO_ID_5395194296248940994" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;If peak heights are determined at a fixed position, this might introduce appreciable errors in the posteriori quantitative analysis (e.g. exponential fitting). As described in my former post, this could be circumvented in some extent by using parabolic interpolation or peak searching of the maximum in a predefined box.&lt;br /&gt;Nevertheless, integration is a very simple solution as can be appreciated in the figure below. Instead of using the Peak Integrals  tool in the Data Analysis module, I will show now a complementary procedure. Basically, what I have applied to all spectra is the well-known &lt;span style="font-style: italic;"&gt;binning &lt;/span&gt;operation which consists of dividing each spectrum in equally sized (e.g. 0.01 ppm in this case) bins, so that integral (area) of each bin represents a new point in the &lt;span style="font-style: italic;"&gt;binned&lt;/span&gt; spectrum&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_-MfflvAgRls/St-UoVWSddI/AAAAAAAAAgU/sZ2jg7TcMpM/s1600-h/binning.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 279px;" src="http://1.bp.blogspot.com/_-MfflvAgRls/St-UoVWSddI/AAAAAAAAAgU/sZ2jg7TcMpM/s400/binning.jpg" alt="" id="BLOGGER_PHOTO_ID_5395194299259450834" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;As seen in the figure above, binning clearly removes the effect of chemical shift changes but of course, at the cost of a significant reduction in data resolution.&lt;br /&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6953549091784501422-6856420964138923328?l=nmr-analysis.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/6856420964138923328/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='https://www.blogger.com/comment.g?blogID=6953549091784501422&amp;postID=6856420964138923328' title='2 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/6856420964138923328'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/6856420964138923328'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/2009/10/binning-and-nmr-data-analysis.html' title='Binning and NMR Data Analysis'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email><gd:extendedProperty xmlns:gd='http://schemas.google.com/g/2005' name='OpenSocialUserId' value='16047913759663550274'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_-MfflvAgRls/St-UoKIhucI/AAAAAAAAAgM/Tzp-FliKYd8/s72-c/Misalignment.jpg' height='72' width='72'/><thr:total xmlns:thr='http://purl.org/syndication/thread/1.0'>2</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6953549091784501422.post-5681759935933005603</id><published>2009-10-21T04:16:00.000-07:00</published><updated>2009-10-21T07:11:17.893-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Arrayed NMR'/><category scheme='http://www.blogger.com/atom/ns#' term='NMR Analysis'/><title type='text'>Basics on Arrayed-NMR Data Analysis (Part IV)</title><content type='html'>&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;Next up in my survey on &lt;/span&gt;&lt;span style="font-weight: bold;font-size:100%;" &gt;analysis of arrayed NMR experiments&lt;/span&gt;&lt;span style="font-size:100%;"&gt; ( View Parts &lt;a href="http://nmr-analysis.blogspot.com/2009/10/basis-on-arrayed-nmr-data-analysis-part.html"&gt;1&lt;/a&gt;, &lt;a href="http://nmr-analysis.blogspot.com/2009/10/basics-on-arrayed-nmr-data-analysis.html"&gt;2&lt;/a&gt;, &lt;a href="http://nmr-analysis.blogspot.com/2009/10/basics-on-arrayed-nmr-data-analysis_14.html"&gt;3&lt;/a&gt; ) takes me to a quick overview of the different methods of data evaluation, such as the determination of peak heights and peak areas from arrayed experiments. Here you go...&lt;/span&gt;&lt;br /&gt;&lt;hr /&gt;&lt;span style="font-size:100%;"&gt;&lt;br /&gt;Of the different existing methods for the extraction of peak intensities from arrayed NMR spectra (see [1] ), Mnova provides the following ones: &lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-weight: bold;font-size:130%;" &gt;(1) Peak area integration&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;This is the default method in Mnova Data Analysis module (see figure below)&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_-MfflvAgRls/St7wEHFStdI/AAAAAAAAAfc/Y1A5N9sNeRE/s1600-h/PeakAreaUI.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 330px; height: 179px;" src="http://3.bp.blogspot.com/_-MfflvAgRls/St7wEHFStdI/AAAAAAAAAfc/Y1A5N9sNeRE/s400/PeakAreaUI.jpg" alt="" id="BLOGGER_PHOTO_ID_5395013357047821778" border="0" /&gt;&lt;/a&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;T&lt;/span&gt;&lt;span style="font-size:100%;"&gt;his method consists of a standard numeric integration over the whole peak. Basically, the program is summing up all the points within the selected area of interest) as illustrated in the figure below:&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_-MfflvAgRls/St7wDzz9tqI/AAAAAAAAAfU/koBXXHIPfas/s1600-h/PeakAreas.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 279px;" src="http://1.bp.blogspot.com/_-MfflvAgRls/St7wDzz9tqI/AAAAAAAAAfU/koBXXHIPfas/s400/PeakAreas.jpg" alt="" id="BLOGGER_PHOTO_ID_5395013351874868898" border="0" /&gt;&lt;/a&gt;&lt;/span&gt;&lt;span style="font-size:100%;"&gt;This figure has been created as follow: two identical Lorentzian lines (green &amp;amp; red) were simulated and then noise was added.  The noise level is the same in both spectra but obviously, the actual numbers are different (more technically, noise in both spectra was calculated using a different seed in the random number generator).&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;This peak area method for data extraction is quite robust to noise (provided that the noise level is more or less constant across the different spectra in the arrayed experiment) and more importantly, insensitive to chemical shift fluctuations from trace to trace in the experiment, a situation which is more frequent than generally realized. For these reasons, and for its simplicity of use, this is method of choice for well-resolved peaks.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;If the peaks of interest exhibit some degree of overlap, this method is not very reliable and some of the next methods will be more convenient&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;&lt;span style="font-weight: bold;"&gt;(2) Peak Height Measurement&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;This is the second method for data extraction (see figure below) and it finds the peak height at a given chemical shift across all the spectra in the arrayed experiment.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_-MfflvAgRls/St7w4lwa6DI/AAAAAAAAAgE/ct1yrkZU6aQ/s1600-h/PeakHeightsUI.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 330px; height: 179px;" src="http://1.bp.blogspot.com/_-MfflvAgRls/St7w4lwa6DI/AAAAAAAAAgE/ct1yrkZU6aQ/s400/PeakHeightsUI.jpg" alt="" id="BLOGGER_PHOTO_ID_5395014258634975282" border="0" /&gt;&lt;/a&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;By default, the program will find the peak intensity at the position indicated by the user (using a vertical cursor) and then it will perform a parabolic interpolation in order to refine the value. In addition, the user can specify an interval in such a way that the program will find the maximum peak within that region. This can be done in 2 different ways:&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;ul style="text-align: justify;"&gt;&lt;li&gt;&lt;span style="font-size:100%;"&gt;i) If you click in the Options button, you can define whether you want to use Parabolic and the interval in which the maximum should be found (in ppm&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_-MfflvAgRls/St7w3rBZWmI/AAAAAAAAAf0/j35YBXM4-x4/s1600-h/Options.gif"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 203px; height: 199px;" src="http://4.bp.blogspot.com/_-MfflvAgRls/St7w3rBZWmI/AAAAAAAAAf0/j35YBXM4-x4/s400/Options.gif" alt="" id="BLOGGER_PHOTO_ID_5395014242868484706" border="0" /&gt;&lt;/a&gt;&lt;/span&gt;&lt;/div&gt;&lt;ul style="text-align: justify;"&gt;&lt;li&gt;&lt;span style="font-size:100%;"&gt;(ii) Alternatively, once a peak has been selected, you can change the interval by direct editing of the peak selection model. In the figure below, I’m showing how the peak selection model is PeakIntensity. The first number (6.001 in the figure) corresponds to the central chemical shift whereas the second number (0.100 in the figure) represents the interval for the peak maximum search.&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;div style="text-align: justify;"&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_-MfflvAgRls/St7wDnzKkzI/AAAAAAAAAfM/OSCnUMGQoBE/s1600-h/PeakSelectionEditing.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 396px; height: 236px;" src="http://1.bp.blogspot.com/_-MfflvAgRls/St7wDnzKkzI/AAAAAAAAAfM/OSCnUMGQoBE/s400/PeakSelectionEditing.jpg" alt="" id="BLOGGER_PHOTO_ID_5395013348650292018" border="0" /&gt;&lt;/a&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;Parabolic interpolation is useful because it minimizes the problems caused by the random noise. For example, let’s assume that Parabolic interpolation is not used so that peak heights extraction will be done always at the same fixed chemical shift position (see figure below). As described in reference [1] and illustrated in the figure below, when this method is used the values are seen to be quite different in the two cases: here the precision of the measurement will depend strongly on the noise.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_-MfflvAgRls/St7wEY6-GSI/AAAAAAAAAfk/MOO0KmBJWkA/s1600-h/PeakHeight.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 186px;" src="http://4.bp.blogspot.com/_-MfflvAgRls/St7wEY6-GSI/AAAAAAAAAfk/MOO0KmBJWkA/s400/PeakHeight.jpg" alt="" id="BLOGGER_PHOTO_ID_5395013361836366114" border="0" /&gt;&lt;/a&gt;Parabolic interpolation and/or measurement of the intensity as the maximum height within a fixed box around the peak will help to minimize the effects of movements on the chemical shift position of the peaks due to, for example, temperature instability, pH changes, etc.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;For convenience, Mnova includes the so-called &lt;span style="font-style: italic;"&gt;Pick Max. Peak&lt;/span&gt; method which is totally equivalent to the previous one but it allows the graphical selection of the left and right boundaries in which the maximum peak will be searched for.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;In a nutshell, peak height measurement can be used in those cases in which peak overlap might represent a problem. However, it should be noted that if for some reasons the line widths of the peaks under analysis change from trace to trace, peak heights will not represent a reliable measurement and peak integrals should be used instead.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;In general, I would recommend peak integrals as the most general-purpose method for quantitation of peak intensities in arrayed experiments.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;In the next post of these series I will address the problem of exponential fitting useful in relaxation and diffusion experiments.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-weight: bold;font-size:130%;" &gt;References:&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;[1] Viles JH, Duggan BM, Zaborowski E, Schwarzinger S, Huntley JJA, Kroon GJA, Dyson HJ, Wright PE. 2001. Potential bias in NMR relaxation data introduced by peak intensity analysis and curve fitting methods. J Biomol NMR 21:1–9 (&lt;a href="http://http//www.springerlink.com/content/p527n2847x82250x/"&gt;link&lt;/a&gt;)&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6953549091784501422-5681759935933005603?l=nmr-analysis.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/5681759935933005603/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='https://www.blogger.com/comment.g?blogID=6953549091784501422&amp;postID=5681759935933005603' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/5681759935933005603'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/5681759935933005603'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/2009/10/basics-on-arrayed-nmr-data-analysis_21.html' title='Basics on Arrayed-NMR Data Analysis (Part IV)'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email><gd:extendedProperty xmlns:gd='http://schemas.google.com/g/2005' name='OpenSocialUserId' value='16047913759663550274'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_-MfflvAgRls/St7wEHFStdI/AAAAAAAAAfc/Y1A5N9sNeRE/s72-c/PeakAreaUI.jpg' height='72' width='72'/><thr:total xmlns:thr='http://purl.org/syndication/thread/1.0'>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6953549091784501422.post-4278670681382829220</id><published>2009-10-14T03:02:00.000-07:00</published><updated>2009-10-20T00:06:52.356-07:00</updated><title type='text'>Basics on Arrayed-NMR Data Analysis (Part III): Extracting and calculating useful NMR related molecular information</title><content type='html'>&lt;div style="text-align: justify;"&gt;After the basic introductory posts on arrayed NMR experiments, it’s now time to get some action and see how to extract relevant information from these experiments and calculate useful NMR related parameters such as diffusion, relaxation times, kinetics constants, etc.&lt;br /&gt;&lt;br /&gt;Actually, in this post I will cover the first case, that is, the analysis of PFG experiments to calculate diffusion coefficients. The reason for this is twofold: (1) I have a nice PFG data set whilst the quality of the relaxation experiments I currently have access to is quite poor (if any of you have any good relaxation data and can send them over, I would be very grateful) (2) The current version of Mnova has been optimized to handle PFG experiments fully automatically whilst some simple manual intervention is needed when working with other arrayed-like NMR experiments. However, I would like to emphasize that, for example, relaxation experiments are already fully supported in the current version of Mnova, although it is necessary to enter the time delays manually in the program (this is very simple, btw). Automation of relaxation experiments is already possible with alpha versions of Mnova.&lt;br /&gt;&lt;br /&gt;This is how a PFG experiment can be analyzed with &lt;a href="http://mestrelab.com/Products/Mnova-NMR/Details.html"&gt;Mnova &lt;/a&gt;with the Data Analysis module (for your information, Mnova includes a DOSY-like processing algorithm based on a Bayesian Algorithm. See this&lt;a href="http://mestrelab.com/dosy.html"&gt; http://mestrelab.com/dosy.html&lt;/a&gt; and this &lt;a href="http://nmr-analysis.blogspot.com/2008/09/baydosy-whats-under-hood.html"&gt;http://nmr-analysis.blogspot.com/2008/09/baydosy-whats-under-hood.html&lt;/a&gt;   for more information):&lt;br /&gt;&lt;br /&gt;Once the arrayed spectra has been loaded into Mnova, issue menu command Analysis/Data Analysis. The so-called Data Analysis widget will popup. This will be the central control panel (see figure below) for anything related to the analysis of arrayed experiments.&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;div style="text-align: justify;"&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_-MfflvAgRls/StWk5PpSEhI/AAAAAAAAAdc/BajKnXh1ih0/s1600-h/DataAnalysis3_1.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 260px;" src="http://2.bp.blogspot.com/_-MfflvAgRls/StWk5PpSEhI/AAAAAAAAAdc/BajKnXh1ih0/s400/DataAnalysis3_1.jpg" alt="" id="BLOGGER_PHOTO_ID_5392397432205218322" border="0" /&gt;&lt;/a&gt;Its operation is very simple. The first thing you have to do is click on the New button. As a result, Mnova will populate the X-Y Table with some initial values (as described in a moment) and create a new item, the so-called Data Analysis Plot. This new item will display the values from the X-Y Table which in general are the values extracted from the arrayed spectra, both experimental (Y) and fitted (Y’).&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_-MfflvAgRls/StWlDk9b0jI/AAAAAAAAAdk/ZeIXsNGQoPI/s1600-h/DataAnalysis3_2.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 262px;" src="http://1.bp.blogspot.com/_-MfflvAgRls/StWlDk9b0jI/AAAAAAAAAdk/ZeIXsNGQoPI/s400/DataAnalysis3_2.jpg" alt="" id="BLOGGER_PHOTO_ID_5392397609725579826" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;&lt;span style="font-weight: bold;"&gt;The X-Y Table&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;This table is composed by one X column, X(I), one or several Y-columns (Y, Y1, Y2, etc) to hold the experimental values extracted from the arrayed spectra and one or several Y’-columns which hold the fitted values of their Y counterpart columns.&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;span style="font-weight: bold;"&gt;X-Column&lt;/span&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;When the table is initialized, in the case of PFG experiments the X-column is populated with the Z values from the Diffusion table, that is, the gradient strengths scaled by taking into account the constants from the selected Tanner-Stejskal model. In the case of a relaxation experiment, the X column will contain the time delays. Of course, it is possible to change the contents of the X-column by following any of these methods:&lt;br /&gt;&lt;/div&gt;&lt;ul&gt;&lt;li&gt;Manual editing of the individual cells&lt;span style="text-decoration: underline;"&gt;&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_-MfflvAgRls/StWlPFeti5I/AAAAAAAAAds/rnwRq8RFzOw/s1600-h/DataAnalysis3_3.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 309px; height: 156px;" src="http://1.bp.blogspot.com/_-MfflvAgRls/StWlPFeti5I/AAAAAAAAAds/rnwRq8RFzOw/s400/DataAnalysis3_3.jpg" alt="" id="BLOGGER_PHOTO_ID_5392397807433649042" border="0" /&gt;&lt;/a&gt;&lt;ul style="text-align: justify;"&gt;&lt;li&gt;Copy &amp;amp; paste from a text file. For example, you can put  the values for the X-column into a text (ASCII) file and then paste its contents into the table. To do that, just right click on the first cell you want the paste action to start from.&lt;/li&gt;&lt;/ul&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_-MfflvAgRls/StWlgxwt3fI/AAAAAAAAAd0/IEhJqT4_E1k/s1600-h/DataAnalysis3_4.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 324px; height: 164px;" src="http://4.bp.blogspot.com/_-MfflvAgRls/StWlgxwt3fI/AAAAAAAAAd0/IEhJqT4_E1k/s400/DataAnalysis3_4.jpg" alt="" id="BLOGGER_PHOTO_ID_5392398111378103794" border="0" /&gt;&lt;/a&gt;&lt;ul style="text-align: justify;"&gt;&lt;li&gt;Enter a formula into the Model cell. Double click on the X(I) model cell (1) and then enter the appropriate equation to populate the X column (2). For example, if you simply enter I, the X column will be filled in with numbers 1, 2,3, etc. If you enter a formula like 10+25*I, the X column will be filled with numbers 35,60, 85, etc.&lt;/li&gt;&lt;/ul&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_-MfflvAgRls/StWlnv9PRuI/AAAAAAAAAd8/HOWzaSQPLng/s1600-h/DataAnalysis3_5.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 269px;" src="http://1.bp.blogspot.com/_-MfflvAgRls/StWlnv9PRuI/AAAAAAAAAd8/HOWzaSQPLng/s400/DataAnalysis3_5.jpg" alt="" id="BLOGGER_PHOTO_ID_5392398231152838370" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span style="font-weight: bold;"&gt;Y-Column&lt;/span&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;In all cases, when the table is initialized, the Y-column is automatically filled in with values 1,2,3, etc.  The purpose of this column is to hold the experimental values from the arrayed experiment. For example, in the case of a PFG experiment, it may contain how the intensity (or integral) of a given peak (or set of peaks) evolves as the applied pulse field gradient changes. Likewise, in the case of T1/T2 experiments, this column will show the relaxation profile of a given resonance (or set of resonances). So the question is: how to populate the Y-column with actual information from the spectra?&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;div style="text-align: justify;"&gt;This is again very easy. There is a graphical way (mouse driven) and a manual one. Let’s start with the graphical method:&lt;br /&gt;&lt;/div&gt;&lt;ul&gt;&lt;li style="text-align: justify;"&gt;&lt;span style="font-weight: bold;"&gt;Graphical Selection: &lt;/span&gt;Click on the ‘Interactive Y Filling’ button (see red-highlighted button in the image below). After doing this, the cursor will change into an integral shaped cursor expecting you to select the region from where you want the integrals to be extracted across all the subspectra in the arrayed item. After the selection is done (see figure below), all the integrals will be placed in the Y column and those values will be displayed in the X-Y plot as green crosses (note: the shape, color, etc of these crosses can be customized from the X-Y plot properties).&lt;/li&gt;&lt;/ul&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_-MfflvAgRls/StWlyGjBzdI/AAAAAAAAAeE/XcpHr8FHUeQ/s1600-h/DataAnalysis3_6.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 294px;" src="http://1.bp.blogspot.com/_-MfflvAgRls/StWlyGjBzdI/AAAAAAAAAeE/XcpHr8FHUeQ/s400/DataAnalysis3_6.jpg" alt="" id="BLOGGER_PHOTO_ID_5392398409015610834" border="0" /&gt;&lt;/a&gt; &lt;ul&gt;&lt;li style="text-align: justify;"&gt;&lt;span style="font-weight: bold;"&gt;Manual selection&lt;/span&gt;: if you take a closer look at the Data Analysis table in the figure above, you can appreciate that once the integral region has been selected, the program shows the following text: Integral(4.752, 4.907). This means that we have selected an integral covering that range. This value can be edited manually so that you can specify the limits by simply editing that cell. &lt;/li&gt;&lt;/ul&gt;&lt;span style="font-weight: bold;"&gt;Y’-Column&lt;/span&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;The Y’ column is reserved for the fitted values assuming a particular theoretical model (e.g. a exponential decay). In this particular case, as we are dealing with PFG experiments, we will be interested in the calculation of the Diffusion coefficients and thus, our fitting model could be a mono-exponential decay (multi-exponential decays can also be handled with this module, but I will not address this problem in this post). The process is very simple:&lt;br /&gt;&lt;br /&gt;First click on the Y’(X) cell and then on the small button with 3 points as indicated in the figure below.&lt;br /&gt;&lt;/div&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_-MfflvAgRls/StWl35GjBwI/AAAAAAAAAeM/bGrVjVZH_6w/s1600-h/DataAnalysis3_7.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 372px; height: 343px;" src="http://2.bp.blogspot.com/_-MfflvAgRls/StWl35GjBwI/AAAAAAAAAeM/bGrVjVZH_6w/s400/DataAnalysis3_7.jpg" alt="" id="BLOGGER_PHOTO_ID_5392398508485707522" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;This will launch a dialog box with powerful fitting capabilities.&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_-MfflvAgRls/StWnImvh03I/AAAAAAAAAek/iExZAw89ILk/s1600-h/DataAnalysis3_8.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 237px;" src="http://3.bp.blogspot.com/_-MfflvAgRls/StWnImvh03I/AAAAAAAAAek/iExZAw89ILk/s400/DataAnalysis3_8.jpg" alt="" id="BLOGGER_PHOTO_ID_5392399895126725490" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;This dialog provides two predefined functions useful for fitting mono-exponential data (such as PFG and Relaxation NMR experiments) using either a 2- or a 3-parameter fit. Furthermore, this dialog offers the possibility to enter user customized functions. As this post is already taking too much space, I will leave the details on data fitting for the next post. For the time being, suffice to say that if your problem regards mono-exponential functions, just select any of the 2 predefined functions in the dialog box and click on the Calculate button. Mnova will immediately compute the optimal values, returning these optimal values as well as the fitting  error) and the probability that the acquired series follows the chosen monoexponential model.&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_-MfflvAgRls/StWmRc_lryI/AAAAAAAAAeU/4qgh6Z8XkUU/s1600-h/DataAnalysis3_8_1.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 273px;" src="http://2.bp.blogspot.com/_-MfflvAgRls/StWmRc_lryI/AAAAAAAAAeU/4qgh6Z8XkUU/s400/DataAnalysis3_8_1.jpg" alt="" id="BLOGGER_PHOTO_ID_5392398947616927522" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;Finally, after closing the dialog, it will populate the Y’ column and the X-Y will be updated with the fitted curve (Red line in the figure below).&lt;br /&gt;&lt;/div&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_-MfflvAgRls/StWmZoxZljI/AAAAAAAAAec/jrY80mJWRXo/s1600-h/DataAnalysis3_9.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 97px;" src="http://3.bp.blogspot.com/_-MfflvAgRls/StWmZoxZljI/AAAAAAAAAec/jrY80mJWRXo/s400/DataAnalysis3_9.jpg" alt="" id="BLOGGER_PHOTO_ID_5392399088217593394" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;One nice feature of the Data Analysis module is its ability to handle multiple series. For example, it’s possible to analyze the decay of several resonances within the same experiment. In order to do that, just click on the (+) button to add a new series and repeat the same process to select the desired resonance range and fit the values. For example, in the figure below I’m showing two curves with different decay rates.&lt;br /&gt;&lt;/div&gt;&lt;div style="text-align: justify;"&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_-MfflvAgRls/StWnS7hToGI/AAAAAAAAAes/RKl8KRa0ieE/s1600-h/DataAnalysis3_10.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 182px;" src="http://2.bp.blogspot.com/_-MfflvAgRls/StWnS7hToGI/AAAAAAAAAes/RKl8KRa0ieE/s400/DataAnalysis3_10.jpg" alt="" id="BLOGGER_PHOTO_ID_5392400072502911074" border="0" /&gt;&lt;/a&gt;In my next post I will cover some more details about the different methods available to select the intensities/integrals from the spectra and some basic points on the fitting algorithm.&lt;br /&gt;BTW, you can &lt;a href="http://www.mestrec.com/carlosblog/PFGSample.mnova"&gt;download the full PFG data set used in this post&lt;/a&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6953549091784501422-4278670681382829220?l=nmr-analysis.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/4278670681382829220/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='https://www.blogger.com/comment.g?blogID=6953549091784501422&amp;postID=4278670681382829220' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/4278670681382829220'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/4278670681382829220'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/2009/10/basics-on-arrayed-nmr-data-analysis_14.html' title='Basics on Arrayed-NMR Data Analysis (Part III): Extracting and calculating useful NMR related molecular information'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email><gd:extendedProperty xmlns:gd='http://schemas.google.com/g/2005' name='OpenSocialUserId' value='16047913759663550274'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_-MfflvAgRls/StWk5PpSEhI/AAAAAAAAAdc/BajKnXh1ih0/s72-c/DataAnalysis3_1.jpg' height='72' width='72'/><thr:total xmlns:thr='http://purl.org/syndication/thread/1.0'>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6953549091784501422.post-5184990226998983473</id><published>2009-10-09T07:24:00.000-07:00</published><updated>2009-10-09T07:45:54.997-07:00</updated><title type='text'>Basics on Arrayed-NMR Data Analysis (Part II): Practical hints</title><content type='html'>&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;Further to my previous post, I will cover today some more basic tools available in Mnova for the analysis of NMR arrayed experiments. In particular, I will touch on the following points:&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;How to use different display modes for 1D arrayed spectra&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;How to navigate throughout the different subspectra in the arrayed item&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;How to process individual spectra separately&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;When an &lt;span style="font-weight: bold;"&gt;arrayed experiment&lt;/span&gt; has been detected, all subspectra are grouped together and plotted in the stacked display mode in Mnova (see figure below). Several points are worth mentioning:&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;span style="font-style: italic; font-weight: bold;"&gt;(A)&lt;/span&gt;. Take a look at the green box in the figure below: it shows the so-called ‘&lt;span style="font-weight: bold; font-style: italic;"&gt;active spectrum&lt;/span&gt;’. What does this mean?&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_-MfflvAgRls/Ss9KMzPVxQI/AAAAAAAAAc0/1bgW5G-H9aI/s1600-h/Stacked.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 269px;" src="http://2.bp.blogspot.com/_-MfflvAgRls/Ss9KMzPVxQI/AAAAAAAAAc0/1bgW5G-H9aI/s400/Stacked.jpg" alt="" id="BLOGGER_PHOTO_ID_5390608862759208194" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;The concept of &lt;span style="font-weight: bold; font-style: italic;"&gt;active spectrum&lt;/span&gt; is easier to illustrate with the following example: as I wrote in my previous post, in general all the spectra in an arrayed item are processed exactly with the same processing operations. For example, same level of zero filling, same apodization function, same FT type, same phase correction, etc. However, it i’s possible that some particular spectra require a slightly different processing, independently from the others. In order to do that, it i’s necessary to deactivate the &lt;span style="font-style: italic;"&gt;‘Apply Processing to All spectra in Stack’&lt;/span&gt; option.&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_-MfflvAgRls/Ss9KNaJCfQI/AAAAAAAAAc8/1F2QIv65qRc/s1600-h/ProcessActiveOnly.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 296px;" src="http://1.bp.blogspot.com/_-MfflvAgRls/Ss9KNaJCfQI/AAAAAAAAAc8/1F2QIv65qRc/s400/ProcessActiveOnly.jpg" alt="" id="BLOGGER_PHOTO_ID_5390608873201761538" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;So if that option is off, any processing operation will be applied only to the active spectrum in the stack.&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;The question is: how can we change the &lt;span style="font-weight: bold; font-style: italic;"&gt;active spectrum&lt;/span&gt;? There are 3 different ways:&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;ol&gt;&lt;li&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;Just click on the spectrum you want to be active. This is probably the most intuitive way.&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;Use SHIFT + Mouse Wheel to navigate throughout all the spectra in the stack, one after the other. &lt;/span&gt;&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;Use SHIFT + Up/Down arrow keys. This is analogous to point 2) &lt;/span&gt;&lt;/span&gt;&lt;/li&gt;&lt;/ol&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-family: arial;"&gt;&lt;span style="font-style: italic; font-weight: bold;"&gt;(B)&lt;/span&gt;. If the number of subspectra (traces) is large (e.g. &gt; 10), working in the stack mode might not be very practical. Quite often, working only with the &lt;span style="font-style: italic; font-weight: bold;"&gt;active spectrum&lt;/span&gt; on the screen will be a much better option. This mode can be activated as shown in the image below.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_-MfflvAgRls/Ss9KN_XCNJI/AAAAAAAAAdE/y_QWtXcHiQ0/s1600-h/ActiveSpectrum.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 364px; height: 202px;" src="http://3.bp.blogspot.com/_-MfflvAgRls/Ss9KN_XCNJI/AAAAAAAAAdE/y_QWtXcHiQ0/s400/ActiveSpectrum.jpg" alt="" id="BLOGGER_PHOTO_ID_5390608883192575122" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;/div&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;While working on this mode, you will see on the screen just the &lt;span style="font-weight: bold; font-style: italic;"&gt;active spectrum&lt;/span&gt;. Should you want to move to another spectrum without resorting to the stack mode, just use methods 2) and 3) described above (Shift+Mouse Wheel or Shift + Up/Down keys). &lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;span style="font-size:85%;"&gt;&lt;span style="font-style: italic;"&gt;IMPORTANT&lt;/span&gt;: Remember that even if only the active spectrum is visible, unless the &lt;span style="font-style: italic;"&gt;“Apply Processing to All spectra in Stack&lt;/span&gt;” option is off, all spectra in the stack will also be processed.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-weight: bold; font-style: italic;"&gt;(C)&lt;/span&gt; Another useful display mode consists of superimposing all subspectra (see figure below). This method is very useful, for example, when you want to check whether some peaks shift their position (for instance, due to differences in pH, temperature, etc., as is common in biofluids spectra).&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_-MfflvAgRls/Ss9KOK8-57I/AAAAAAAAAdM/qkzSlyavK7E/s1600-h/Superimposed.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 285px;" src="http://4.bp.blogspot.com/_-MfflvAgRls/Ss9KOK8-57I/AAAAAAAAAdM/qkzSlyavK7E/s400/Superimposed.jpg" alt="" id="BLOGGER_PHOTO_ID_5390608886304532402" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family: arial;"&gt;Finally, there is an additional display mode, the so called &lt;span style="font-weight: bold; font-style: italic;"&gt;whitewashed stacked plot&lt;/span&gt;. The &lt;span style="font-style: italic;"&gt;whitewashing &lt;/span&gt;effect means that the spectra at the front of the display hide the spectra behind them from view, as depicted in the figure below.&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_-MfflvAgRls/Ss9KOv9iqhI/AAAAAAAAAdU/sFXqSGWv88s/s1600-h/whitewashed.jpeg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 191px;" src="http://2.bp.blogspot.com/_-MfflvAgRls/Ss9KOv9iqhI/AAAAAAAAAdU/sFXqSGWv88s/s400/whitewashed.jpeg" alt="" id="BLOGGER_PHOTO_ID_5390608896238987794" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;/span&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family: arial;"&gt;This plotting mode can be useful to create nice reports, but it’s important to emphasize that drawing time will be significantly higher than with the other plotting modes, so it is not recommended when processing the spectra in real time (e.g. interactive phase correction).&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family: arial;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;span style="font-family: arial;"&gt;In my next post I will show how to extract useful information from arrayed spectra.&lt;/span&gt;&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6953549091784501422-5184990226998983473?l=nmr-analysis.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/5184990226998983473/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='https://www.blogger.com/comment.g?blogID=6953549091784501422&amp;postID=5184990226998983473' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/5184990226998983473'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/5184990226998983473'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/2009/10/basics-on-arrayed-nmr-data-analysis.html' title='Basics on Arrayed-NMR Data Analysis (Part II): Practical hints'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email><gd:extendedProperty xmlns:gd='http://schemas.google.com/g/2005' name='OpenSocialUserId' value='16047913759663550274'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_-MfflvAgRls/Ss9KMzPVxQI/AAAAAAAAAc0/1bgW5G-H9aI/s72-c/Stacked.jpg' height='72' width='72'/><thr:total xmlns:thr='http://purl.org/syndication/thread/1.0'>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6953549091784501422.post-7520112631990050497</id><published>2009-10-06T04:08:00.000-07:00</published><updated>2009-10-06T09:50:16.766-07:00</updated><title type='text'>Basics on Arrayed-NMR Data Analysis (part I)</title><content type='html'>&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;In this post I will cover some basic concepts on the analysis of a very important class of NMR experiments, the so-called &lt;span style="font-weight: bold; font-style: italic;"&gt;Arrayed NMR spectra&lt;/span&gt;. The concept is very simple: an arrayed experiment is basically a set of individual spectra acquired sequentially and related to each other through the variation of one or more parameters and finally grouped together to constitute a composite experiment. These experiments are also known as ‘&lt;span style="font-weight: bold; font-style: italic;"&gt;pseudo-2D&lt;/span&gt;’. For example, in the case of Bruker spectra they have the same file name as 2D spectra, that is ser files (ser = serial spectra) . In the case of Varian, the file name is fid (Varian uses the same name for 1D, 2D, 3D, … and arrayed spectra). However, unlike with actual 2D spectra, arrayed spectra are only transformed along the F2 –horizontal or direct- dimension (assuming 1D arrayed spectra only). &lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;/div&gt;&lt;div style="text-align: justify;"&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;The modus operandi is better explained with an example: let’s suppose it is necessary to acquire a pulse field gradient (PFG) experiment. Instead of acquiring independent spectra, it is more convenient to create an array with increasing PFG amplitudes. All resulting spectra are now treated as a single experiment. This grouping greatly facilitates processing as, in general, all subspectra require the same processing operations (apart from some occasional minor adjustments of one or several spectra).  More about this in a moment. &lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;/div&gt;&lt;/div&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;Well known examples of NMR arrayed experiments are, among others:&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;ul&gt;&lt;li&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;Relaxation (T1, T2) &lt;/span&gt;&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt; PFG experiments (DOSY)&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt; Kinetics and reaction monitoring by NMR&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;div style="text-align: justify;"&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;Any good NMR processing software should be able to automatically recognize when an NMR spectrum is an arrayed experiment and will setup all processing operations accordingly. For example, the figure below illustrates the results obtained when a Bruker arrayed folder is dragged and dropped into Mnova:&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;/div&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_-MfflvAgRls/SssmHb1c8RI/AAAAAAAAAcs/EC2nOCGO4fs/s1600-h/DataAnalysis1.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 314px;" src="http://3.bp.blogspot.com/_-MfflvAgRls/SssmHb1c8RI/AAAAAAAAAcs/EC2nOCGO4fs/s400/DataAnalysis1.jpg" alt="" id="BLOGGER_PHOTO_ID_5389443288251822354" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;What has happened here are basically 2 things:&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;ol&gt;&lt;li style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;First, Mnova detects that the dropped folder contains an arrayed experiment&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;&lt;li style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt; With that knowledge in hand, Mnova proceeds to process all the individual spectra, one after the other and of course, along the only valid dimension (F2). So for every spectrum, Mnova applies appropriate weighting, zero filling, FT, phase correction, etc and stacks all the spectra as shown in the picture above&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;&lt;/ol&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;As a result, all individual spectra grouped within one composite item (i.e. arrayed item) have been processed in the same way. However, it’s very common that some subspectra might require independent tuning. For example, many PFG NMR experiments present gradient dependent phase shift so that it becomes necessary to adjust the phase of some individual spectra separately.  This is very easy to accomplish with Mnova and it will be the subject of my next post.&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6953549091784501422-7520112631990050497?l=nmr-analysis.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/7520112631990050497/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='https://www.blogger.com/comment.g?blogID=6953549091784501422&amp;postID=7520112631990050497' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/7520112631990050497'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/7520112631990050497'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/2009/10/basis-on-arrayed-nmr-data-analysis-part.html' title='Basics on Arrayed-NMR Data Analysis (part I)'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email><gd:extendedProperty xmlns:gd='http://schemas.google.com/g/2005' name='OpenSocialUserId' value='16047913759663550274'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_-MfflvAgRls/SssmHb1c8RI/AAAAAAAAAcs/EC2nOCGO4fs/s72-c/DataAnalysis1.jpg' height='72' width='72'/><thr:total xmlns:thr='http://purl.org/syndication/thread/1.0'>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6953549091784501422.post-3996727067367523068</id><published>2008-11-10T03:49:00.000-08:00</published><updated>2009-10-02T02:36:13.854-07:00</updated><title type='text'>MestReS: A Virtual NMR Spectrometer</title><content type='html'>&lt;div style="text-align: justify;"&gt;Aircraft pilots use cockpit flight simulators since they are considerably less expensive to operate than actual aircraft and provide an opportunity to practice crisis problem solving without putting real people or aircraft at risk. Following the same principle, MestReS is a virtual NMR simulator package intended to allow students to learn and practice the NMR instrumental techniques while saving rather expensive spectrometer time and avoiding equipment damage due to improper use. MestReS provides real-time simulation of the processes of field locking, shimming and acquisition. Both continuous-wave (Bruker spectrometers) and FT (Varian spectrometers) deuterium channel simulation are included. Most common physical properties (e.g. sweep rate variation, spinning sidebands, etc) can also be simulated. The program provides basic 1D processing and includes the tools needed to effortlessly create 1H and 13C NMR databases from synthetic FID’s&lt;br /&gt;&lt;/div&gt;&lt;div style="text-align: justify;"&gt;&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_-MfflvAgRls/SRgg9Jg7smI/AAAAAAAAATE/Iv5pqm_ZLZg/s1600-h/MestReS.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 289px;" src="http://2.bp.blogspot.com/_-MfflvAgRls/SRgg9Jg7smI/AAAAAAAAATE/Iv5pqm_ZLZg/s400/MestReS.jpg" alt="" id="BLOGGER_PHOTO_ID_5266995999107953250" border="0" /&gt;&lt;/a&gt;&lt;span style="font-family:arial;"&gt;You can download it from the link below:&lt;br /&gt;&lt;a href="http://www.mestrelab.com/mestres.html"&gt;&lt;br /&gt;&lt;span style="font-weight: bold;"&gt;Download MestReS &lt;/span&gt;&lt;/a&gt;&lt;span style="font-weight: bold;"&gt;at the &lt;/span&gt;&lt;a style="font-weight: bold;" href="http://www.mestrelab.com/Products.html"&gt;Mestrelab Research Chemistry Software Product Page&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;MestReS can emulate  locking and shimming effects in real time. Both continuous-wave (Bruker spectrometers) and FT (Varian spectrometers) deuterium channel simulation are included. Emulation of most commonly used shimming coils (Z,Z2..X,Y) is also provided. Most common physical properties are also simulated (sweep rate variation, spinning sidebands, etc) giving to the student a very realistic  feeling.&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;/div&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_-MfflvAgRls/SRghmYj5Z0I/AAAAAAAAATM/OddgPC8G4lA/s1600-h/LockShimming.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 314px;" src="http://1.bp.blogspot.com/_-MfflvAgRls/SRghmYj5Z0I/AAAAAAAAATM/OddgPC8G4lA/s400/LockShimming.jpg" alt="" id="BLOGGER_PHOTO_ID_5266996707521554242" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-family:arial;"&gt;While we offer MestReS as a totally free program, we are not longer developing it further or offering technical support for its use. Nevertheless, should you have any comment on the program, feel free to let me know.&lt;/span&gt;&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;I would particularly like to thank Armando Navarro, of the University of Santiago de Compostela, for his work in developing MestReS and making it available to our user community. It was a pleasure to collaborate with him on this project while I was working at the University&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6953549091784501422-3996727067367523068?l=nmr-analysis.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/3996727067367523068/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='https://www.blogger.com/comment.g?blogID=6953549091784501422&amp;postID=3996727067367523068' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/3996727067367523068'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/3996727067367523068'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/2008/11/mestres-virtual-nmr-spectrometer.html' title='MestReS: A Virtual NMR Spectrometer'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email><gd:extendedProperty xmlns:gd='http://schemas.google.com/g/2005' name='OpenSocialUserId' value='16047913759663550274'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_-MfflvAgRls/SRgg9Jg7smI/AAAAAAAAATE/Iv5pqm_ZLZg/s72-c/MestReS.jpg' height='72' width='72'/><thr:total xmlns:thr='http://purl.org/syndication/thread/1.0'>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6953549091784501422.post-7402054842266041892</id><published>2008-10-10T04:11:00.000-07:00</published><updated>2009-10-02T02:35:42.689-07:00</updated><title type='text'>MestReJ: A free tool for the prediction of vicinal proton-proton 3J(HH) coupling constants</title><content type='html'>&lt;div style="text-align: justify;"&gt;Scalar coupling constants are sensitive to the geometrical features of a molecule and therefore, their magnitude provides a direct insight into the geometry and electronic structure of a molecule. For example, the Karplus equation [J. Chem. Phys., 30, 11 (1959), J. Am. Chem. Soc., 85, 2870 (1963)] describes the relationship between the 3J coupling constant and the dihedral angle between vicinal hydrogens.&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_-MfflvAgRls/SO86CHbxaWI/AAAAAAAAAM0/ap3ZZEXl8YU/s1600-h/karplus.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer;" src="http://3.bp.blogspot.com/_-MfflvAgRls/SO86CHbxaWI/AAAAAAAAAM0/ap3ZZEXl8YU/s400/karplus.jpg" alt="" id="BLOGGER_PHOTO_ID_5255483098194340194" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;After the pioneering work of &lt;a href="http://pubs.acs.org/cen/science/8151/8151karplus.html"&gt;Karplus&lt;/a&gt;, several other generalized Karplus equations  have been proposed for the mutual dependence of J and the dihedral angle. Among these, Haasnoot-de Leeuw-Altona (HLA) are by far the most widely used. Applications including other generalized Karplus equations are scarce which hinder their general use for the common organic chemist. Such is the case of the more recent and precise Díez-Altona-Donders (DAD) equations, developed by Altona’s group.&lt;br /&gt;&lt;/div&gt;&lt;div style="text-align: justify;"&gt;A few years ago, we developed an easy to use J pocket calculator &lt;span style="font-weight: bold;"&gt;MestReJ &lt;/span&gt;which you can now download directly from the link below and use for free with no strings attached.&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_-MfflvAgRls/SO85Ziw8mAI/AAAAAAAAAMs/EZuw3K4M2tc/s1600-h/MestReJ.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer;" src="http://4.bp.blogspot.com/_-MfflvAgRls/SO85Ziw8mAI/AAAAAAAAAMs/EZuw3K4M2tc/s400/MestReJ.jpg" alt="" id="BLOGGER_PHOTO_ID_5255482401156274178" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span style="font-weight: bold;font-family:arial;" &gt;&lt;a href="http://www.mestrelab.com/mestrej.html"&gt;Download MestReJ&lt;/a&gt; at the &lt;a href="http://www.mestrelab.com/Products.html"&gt;Mestrelab Research Chemistry Software Product Page&lt;/a&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-weight: bold;"&gt;MestReJ &lt;/span&gt;is a very easy little application to work with: it uses a Newman projection of the fragment under observation and a plot of the J values against the torsion angle HCC’H’. It implements the two kinds of generalized Karplus equations developed by the Altona’s group: the classical Haasnoot-de Leeuw-Altona equations and the more recent and precise Díez-Altona-Donders equations. The Colucci-Jungk-Gandour, the Barfield-Smith and the Karplus equations are also implemented in the program. For further information, see this article:&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;&lt;span class="textbold"  style="font-size:85%;"&gt;A Graphical Tool for the Prediction of Vicinal Proton-Proton &lt;sup&gt;3&lt;/sup&gt;&lt;i&gt;J&lt;/i&gt;&lt;sub&gt;HH&lt;/sub&gt; Coupling Constants&lt;/span&gt; &lt;span style="font-size:85%;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;span class="text"  style="font-size:85%;"&gt;Navarro-Vazquez, A.; Cobas, J. C.; Sardina, F. J.; Casanueva, J.; Diez, E.&lt;/span&gt;&lt;span style="font-size:85%;"&gt;&lt;br /&gt;&lt;/span&gt;  &lt;span class="textitalics"  style="font-size:85%;"&gt;J. Chem. Inf. Comput. Sci.;&lt;/span&gt;&lt;span style="font-size:85%;"&gt; &lt;/span&gt;&lt;span style="font-weight: bold;font-size:85%;" class="textbold" &gt;2004&lt;/span&gt;&lt;span style="font-size:85%;"&gt;;                   &lt;/span&gt;&lt;span class="textitalics"  style="font-size:85%;"&gt;44&lt;/span&gt;&lt;span class="text"  style="font-size:85%;"&gt;(5);     1680-1685.&lt;/span&gt;&lt;span style="font-size:85%;"&gt;              &lt;/span&gt;&lt;span class="text"  style="font-size:85%;"&gt;DOI: &lt;a href="http://dx.doi.org/10.1021%2Fci049913t" class="link"&gt;10.1021/ci049913t&lt;/a&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;I hope you will find this application useful in your research&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6953549091784501422-7402054842266041892?l=nmr-analysis.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/7402054842266041892/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='https://www.blogger.com/comment.g?blogID=6953549091784501422&amp;postID=7402054842266041892' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/7402054842266041892'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/7402054842266041892'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/2008/10/mestrej-free-tool-for-prediction-of.html' title='MestReJ: A free tool for the prediction of vicinal proton-proton 3J(HH) coupling constants'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email><gd:extendedProperty xmlns:gd='http://schemas.google.com/g/2005' name='OpenSocialUserId' value='16047913759663550274'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_-MfflvAgRls/SO86CHbxaWI/AAAAAAAAAM0/ap3ZZEXl8YU/s72-c/karplus.jpg' height='72' width='72'/><thr:total xmlns:thr='http://purl.org/syndication/thread/1.0'>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6953549091784501422.post-6795599599294447825</id><published>2008-11-04T15:02:00.000-08:00</published><updated>2009-10-02T02:35:24.226-07:00</updated><title type='text'>EXSYCALC: A free software for NMR analysis of molecular systems undergoing chemical exchange</title><content type='html'>&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;EXSYCALC is a free program intended for the study by NMR of molecular systems undergoing chemical exchange. It does a quantitative analysis of the experimental intensities of the NMR peaks obtained in EXSY experiments to calculate the magnetization exchange rates k' of the exchange equilibrium (related with the reaction rate constants k ). The program allows the calculation of systems with an arbitrary number of exchange sites, spins, populations and arbitrary longitudinal relaxation rates. The calculations are done according to a full relaxation matrix analysis of the intensities. The range of applicability of the approach used requires that the signal of each different species in the exchange process is conveniently separated from the others in the NMR spectrum (i.e. slow chemical exchange in the chemical shift time scale)&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;/div&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;div style="text-align: justify;"&gt;&lt;div style="text-align: center;"&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_-MfflvAgRls/SRDU17SFV2I/AAAAAAAAAOk/Sex-WnRKnxU/s1600-h/EXSYCalcEx1.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 385px; height: 400px;" src="http://3.bp.blogspot.com/_-MfflvAgRls/SRDU17SFV2I/AAAAAAAAAOk/Sex-WnRKnxU/s400/EXSYCalcEx1.jpg" alt="" id="BLOGGER_PHOTO_ID_5264941987307804514" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;You can download it from this link:&lt;br /&gt;&lt;a href="http://www.mestrelab.com/exsycalc.html"&gt;&lt;br /&gt;&lt;/a&gt;&lt;span style="font-weight: bold;"&gt;&lt;span style="font-family: arial;"&gt;&lt;a href="http://www.mestrelab.com/exsycalc.html"&gt;Download EXSYCalc&lt;/a&gt; at the &lt;a href="http://www.mestrelab.com/Products.html"&gt;Mestrelab Research Chemistry Software Product Page&lt;/a&gt;&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;For the calculation of rate constants, the program requires that the user supplies the experimental amplitudes of certain NMR peaks obtained in two different EXSY experiments, one is an EXSY experiment acquired at a certain mixing time (tm), and the other is an EXSY experiment acquired at 0 or very short mixing time (reference experiment). In the former experiment the mixing time (tm) need to be large enough for the magnetization exchange process to take place. In this experiment the amplitudes (intensities) of those signals in exchange, A(tm), have to be quantified for both diagonal and cross peaks. In the other EXSY experiment, the EXSY reference experiment, no cross peaks due to magnetization exchange should be observed (thermal equilibrium) and the amplitudes of just the diagonal peaks of those signals in exchange, A(0), have to be measured. It is important to mention that both experiments must be acquired and processed under identical conditions, temperature, number of scans etc.&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_-MfflvAgRls/SRDVs60i0UI/AAAAAAAAAOs/eb-kinV6_pA/s1600-h/EXSYCALCPicture.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 398px; height: 400px;" src="http://4.bp.blogspot.com/_-MfflvAgRls/SRDVs60i0UI/AAAAAAAAAOs/eb-kinV6_pA/s400/EXSYCALCPicture.jpg" alt="" id="BLOGGER_PHOTO_ID_5264942932076712258" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;Enjoy it!&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;/div&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6953549091784501422-6795599599294447825?l=nmr-analysis.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/6795599599294447825/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='https://www.blogger.com/comment.g?blogID=6953549091784501422&amp;postID=6795599599294447825' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/6795599599294447825'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/6795599599294447825'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/2008/11/exsycalc-free-software-for-nmr-analysis.html' title='EXSYCALC: A free software for NMR analysis of molecular systems undergoing chemical exchange'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email><gd:extendedProperty xmlns:gd='http://schemas.google.com/g/2005' name='OpenSocialUserId' value='16047913759663550274'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_-MfflvAgRls/SRDU17SFV2I/AAAAAAAAAOk/Sex-WnRKnxU/s72-c/EXSYCalcEx1.jpg' height='72' width='72'/><thr:total xmlns:thr='http://purl.org/syndication/thread/1.0'>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6953549091784501422.post-1219751178203380953</id><published>2009-09-16T01:24:00.000-07:00</published><updated>2009-09-16T01:52:54.958-07:00</updated><title type='text'>Mnova 6.0, at last! GSD, Line Fitting, Data Analysis, handling of LC/GC/MS data and much more!</title><content type='html'>&lt;div style="text-align: justify;"&gt;&lt;span style="font-family:arial;"&gt;It's been over 6 weeks since my last post on this blog but don’t worry, I haven’t been idle. On the contrary, I have a very good excuse for this lack of posts: We all at &lt;a href="http://www.mestrelab.com/"&gt;Mestrelab &lt;/a&gt;have been working very hard trying to get version 6.0 of Mnova finished. Now I’m delighted to announce that we have done it and version 6.0 is finally available for download from our Web site. &lt;/span&gt; &lt;span style="font-family:arial;"&gt;This is certainly a major upgrade of the software in which we have put a lot of work and passion. It brings a number of enhancements and bug fixes but most significantly are the following new developments: &lt;/span&gt;&lt;br /&gt;&lt;/div&gt;&lt;div style="text-align: justify;"&gt;&lt;br /&gt;&lt;a href="http://www.mestrelab.com/Products/Mnova-MS/Details.html"&gt;&lt;span style="font-weight: bold;"&gt;&lt;span style="font-size:130%;"&gt;Mnova MS&lt;/span&gt;&lt;/span&gt;&lt;/a&gt;&lt;br /&gt;&lt;/div&gt;&lt;div style="text-align: justify;"&gt;&lt;br /&gt;Yes, Mnova speaks a new language now, not just NMR. Since its conception, Mnova was Multi-document, Multi-Page, Multi-Platform and designed to become Multi-Technique, which it has now done&lt;br /&gt;&lt;/div&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_-MfflvAgRls/SrCiDrLvlkI/AAAAAAAAAcU/ZrtARmsysbE/s1600-h/Mnova-MS.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 279px;" src="http://4.bp.blogspot.com/_-MfflvAgRls/SrCiDrLvlkI/AAAAAAAAAcU/ZrtARmsysbE/s400/Mnova-MS.jpg" alt="" id="BLOGGER_PHOTO_ID_5381979738723030594" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span style="font-weight: bold;font-size:130%;" &gt;GSD (Global Spectral Deconvolution)&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-family:arial;"&gt;I have already &lt;a href="http://nmr-analysis.blogspot.com/2009/06/fighting-against-peak-overlap.html"&gt;blogged about it&lt;/a&gt;, but now GSD is finally available so that you all can try it and play with it. We are confident that this new powerful analysis tool will open new avenues in many NMR fields&lt;/span&gt;&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_-MfflvAgRls/SrChCEU7YUI/AAAAAAAAAcM/KGTxY2QJZ7s/s1600-h/SantoninGSD.jpeg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 279px;" src="http://2.bp.blogspot.com/_-MfflvAgRls/SrChCEU7YUI/AAAAAAAAAcM/KGTxY2QJZ7s/s400/SantoninGSD.jpeg" alt="" id="BLOGGER_PHOTO_ID_5381978611601072450" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;span style="font-weight: bold;font-size:130%;" &gt;NMR Line Fitting (Deconvolution)&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;Even though GSD is a fully automatic spectral deconvolution algorithm, a general purpose line fitting (deconvolution) module is always useful. In an effort to maximize user experience, we have developed a powerful, yet easy to use Graphical User Interface which makes possible both the manual and automatic adjustment of any peaks parameters (i.e. peaks positions, heights, line widths, shapes). I will talk more about it in a new post in a few days&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_-MfflvAgRls/SrCj2GCFbYI/AAAAAAAAAcc/wNZMYh0hWJs/s1600-h/LineFitting.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 241px;" src="http://4.bp.blogspot.com/_-MfflvAgRls/SrCj2GCFbYI/AAAAAAAAAcc/wNZMYh0hWJs/s400/LineFitting.jpg" alt="" id="BLOGGER_PHOTO_ID_5381981704435363202" border="0" /&gt;&lt;/a&gt;&lt;span style="font-weight: bold;font-size:130%;" &gt;&lt;br /&gt;NMR Data Analysis Module&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;Designed for the analysis of arrayed NMR experiments such as DOSY, Relaxation (T1, T2), kinetics, metabonomics, reaction monitoring, etc. This new module includes, among other features, the capability to apply reliable and fast non linear fitting (including specialized mono-exponential fitting), plotting of the experimental and fitted data, etc&lt;br /&gt;&lt;/div&gt;&lt;/div&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_-MfflvAgRls/SrCkNKE7c4I/AAAAAAAAAck/K8l4bQPfKC0/s1600-h/MnovaDataAnalysis.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 241px;" src="http://2.bp.blogspot.com/_-MfflvAgRls/SrCkNKE7c4I/AAAAAAAAAck/K8l4bQPfKC0/s400/MnovaDataAnalysis.jpg" alt="" id="BLOGGER_PHOTO_ID_5381982100658025346" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;Well, this list is not a fair account of all the number of new things implemented in this version. For a detailed list you could check out the ‘&lt;a href="http://mestrelab.com/whats-new-in-mnova.html"&gt;What’s new in 6.0&lt;/a&gt;'. &lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;/div&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;From here I encourage you to try this new version and experiment with the new tools. You can download an evaluation version from our website (at &lt;a href="http://www.blogger.com/www.mestrelab.com"&gt;www.mestrelab.com&lt;/a&gt;). If for some reason your license has already expired, please do not hesitate to get in touch with us at Mestrelab, we will be delighted to supply a license for the software. In the meantime, I can only add that in the next few days I will be creating new posts where I will be revealing in detail each and every new tool of this brand new version as well as some innovative and interesting applications&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;/div&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6953549091784501422-1219751178203380953?l=nmr-analysis.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/1219751178203380953/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='https://www.blogger.com/comment.g?blogID=6953549091784501422&amp;postID=1219751178203380953' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/1219751178203380953'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/1219751178203380953'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/2009/09/mnova-60-at-last-gsd-line-fitting-data.html' title='Mnova 6.0, at last! GSD, Line Fitting, Data Analysis, handling of LC/GC/MS data and much more!'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email><gd:extendedProperty xmlns:gd='http://schemas.google.com/g/2005' name='OpenSocialUserId' value='16047913759663550274'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/_-MfflvAgRls/SrCiDrLvlkI/AAAAAAAAAcU/ZrtARmsysbE/s72-c/Mnova-MS.jpg' height='72' width='72'/><thr:total xmlns:thr='http://purl.org/syndication/thread/1.0'>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6953549091784501422.post-2347931151895446986</id><published>2009-07-28T00:03:00.000-07:00</published><updated>2009-08-12T04:12:21.970-07:00</updated><title type='text'>Agilent Technologies to Acquire Varian</title><content type='html'>&lt;span style="font-family:arial;"&gt;&lt;span style="font-size:100%;"&gt;This morning I got up with this &lt;span style="font-style: italic;"&gt;shocking &lt;/span&gt;news:&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:arial;"&gt;Agilent Technologies to Acquire Varian, Inc. for $1.5 Billion &lt;/span&gt;&lt;br /&gt;&lt;a href="http://www.agilent.com/about/newsroom/presrel/2009/27jul-gp09016.html"&gt;http://www.agilent.com/about/newsroom/presrel/2009/27jul-gp09016.html&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-weight: bold; font-style: italic;"&gt;Note:&lt;/span&gt;&lt;br /&gt;&lt;span style="font-style: italic;"&gt;Just to clarify, the word &lt;span style="font-weight: bold;"&gt;shocking &lt;/span&gt;was used in the sense of &lt;span style="font-weight: bold;"&gt;surprising&lt;/span&gt;, and with no negative connotations meant. Not being privy to the detail of the deal or to Agilent's plans, I can of course not  foresee how this may affect Varian's position in the NMR marketplace or how it may affect the NMR community, although having a big company with a big interest in R&amp;amp;D like Agilent in our market could well be very positive&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:arial;"&gt;&lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6953549091784501422-2347931151895446986?l=nmr-analysis.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/2347931151895446986/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='https://www.blogger.com/comment.g?blogID=6953549091784501422&amp;postID=2347931151895446986' title='1 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/2347931151895446986'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/2347931151895446986'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/2009/07/agilent-technologies-to-acquire-varian.html' title='Agilent Technologies to Acquire Varian'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email><gd:extendedProperty xmlns:gd='http://schemas.google.com/g/2005' name='OpenSocialUserId' value='16047913759663550274'/></author><thr:total xmlns:thr='http://purl.org/syndication/thread/1.0'>1</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6953549091784501422.post-1156727111329168596</id><published>2009-06-05T03:17:00.001-07:00</published><updated>2009-06-05T03:46:47.937-07:00</updated><title type='text'>Fighting against peak overlap – Introducing Global Spectral Deconvolution (GSD)</title><content type='html'>&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;1H NMR is for sure the most powerful technique for structure elucidation, especially for small organic molecules. Typically, an organic chemist uses the chemical shift, coupling constants and integration information contained in an 1H-NMR spectrum to either verify or elucidate an unknown compound. Of course, it’s quite common that a simple 1H-NMR spectrum is not enough to unambiguously confirm a structure and thus other NMR experiments (e.g. 13C-NMR, HSQC, COSY, etc) are used to get more structural information.&lt;/span&gt;&lt;/span&gt;&lt;/div&gt; &lt;div style="text-align: justify;"&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;Nevertheless, I have often found that many organic chemists do not always try to get the most out of 1H-NMR spectra (which is the cheapest experiment), in particular when some multiplets are complex to interpret (strong coupling) or when peaks overlap prevents valuable information to be detected in some multiplets. &lt;span style="color: rgb(255, 255, 0);"&gt;Overlapping peaks and new ways to get around it will be the subject of this post&lt;/span&gt;.&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;/div&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;As it is well known, there are two principal factors limiting the resolution power in a spectrum. First, we have the natural line width limitation imposed by the T2 (spin-spin relaxation). For example, if T2 is about 1 second, the peak linewidth at half height cannot be less than 0.32 Hz (remember, line width at half height = 1 / (pi * T2) = 1 / 3.1415 = 0.32) no matter how powerful is our NMR instrument or the field homogeneity. On the other hand, there are instrumental shortcomings (e.g. spatial uniformity of the applied magnetic field, etc).&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;Nonetheless, there is an additional limiting factor, and whose importance is generally underestimated which has to do with the generally large number of transitions in 1H-NMR spectra. In short, the peaks we can observe in a 1H-NMR are just a small fraction of the actual transition resonances which are not observable because of the limited digital resolution. In fact, &lt;span style="color: rgb(255, 255, 0);"&gt;every peak in an 1H-NMR spectrum is basically an envelope of a large number of transitions and its shape is dominated by the coupling pattern of the spin system&lt;/span&gt;. Even in molecules of modest size the number of distinct peaks is tens to thousands times smaller than that of quantum transitions. As a very simple example, consider an A3B2 spin system. Depending on the second order interaction and on the available digital resolution, we might observe the expected triplet / quadruplet multiplet patterns. This is illustrated in the figure below. &lt;/span&gt;&lt;/span&gt; &lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt; &lt;/span&gt;&lt;/span&gt; &lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_-MfflvAgRls/SijyiSX2QDI/AAAAAAAAAaM/bMAXuEzjNws/s1600-h/A3B2_low.jpeg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 279px;" src="http://2.bp.blogspot.com/_-MfflvAgRls/SijyiSX2QDI/AAAAAAAAAaM/bMAXuEzjNws/s400/A3B2_low.jpeg" alt="" id="BLOGGER_PHOTO_ID_5343787628736430130" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;However, if we use &lt;a href="http://www.mestrelab.com/"&gt;Mnova &lt;/a&gt;capabilities to display all main transitions of any coupled spin system by simply hovering with the mouse over the particle of interest, we can appreciate the additional number of resonances (see below):&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_-MfflvAgRls/SijzNp9jwxI/AAAAAAAAAaU/OS_JIyL4BMU/s1600-h/A3B2Trans.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 172px;" src="http://4.bp.blogspot.com/_-MfflvAgRls/SijzNp9jwxI/AAAAAAAAAaU/OS_JIyL4BMU/s400/A3B2Trans.jpg" alt="" id="BLOGGER_PHOTO_ID_5343788373802992402" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;Furthermore, I can easily increase the digital resolution of the A3B2 spectrum above by just reducing the line width used in the spin simulation module of Mnova. As a result, it’s now possible to observe more resonances in this particular A3B2 spin system (although not all of them, of course):&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_-MfflvAgRls/SijzfH1csrI/AAAAAAAAAac/PqpGqHr41os/s1600-h/A3B2_High.jpeg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 279px;" src="http://3.bp.blogspot.com/_-MfflvAgRls/SijzfH1csrI/AAAAAAAAAac/PqpGqHr41os/s400/A3B2_High.jpeg" alt="" id="BLOGGER_PHOTO_ID_5343788673879814834" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;Of course, this way of increasing the digital resolution is only possible with synthetic spectra and cannot be applied to experimental data. Obviously there are many resolution enhancement techniques being &lt;a href="http://nmr-analysis.blogspot.com/2007/11/resolution-booster.html"&gt;Resolution Booster&lt;/a&gt; one of the most powerful ones. &lt;/span&gt;&lt;/span&gt; &lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;As a nice example of the application of this technique, let me tell you this story:&lt;br /&gt;A couple of weeks ago, a very good friend of mine, a professor of organic chemist, came to me with an interesting structural problem. His research group had carried out a reaction which resulted in one single product whose 1H-NMR spectrum was, in principle, compatible with two potential structures. In order to ambiguously find the right structure, they acquired more NMR spectra (DEPT, HSQC, HMBC, COSY) which allowed them to find the correct molecule However, while discussing the problem having a few beers at a bar in Santiago, we found that just the 1H spectrum was more than enough in order to discard one of the two structures and completely assign the correct one without the necessity to acquire any other NMR experiment.&lt;/span&gt;&lt;/span&gt; &lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;The key was the ability to resolve a long range coupling (homo-allylic) with the assistance of Resolution Booster. Basically, the 1H-NMR showed a clean double doublet which was compatible with both structures (I’m sorry, but I cannot reveal those structures). This multiplet is shown below:&lt;/span&gt;&lt;/span&gt; &lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt; &lt;/span&gt;&lt;/span&gt; &lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_-MfflvAgRls/Sijzv7nGO8I/AAAAAAAAAak/v9QRE8UdlMw/s1600-h/dd.jpeg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 279px;" src="http://4.bp.blogspot.com/_-MfflvAgRls/Sijzv7nGO8I/AAAAAAAAAak/v9QRE8UdlMw/s400/dd.jpeg" alt="" id="BLOGGER_PHOTO_ID_5343788962656172994" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;After appling Resolution Booster, we could clearly appreciate a further splitting which we could assign to the expected homo-allylic coupling with a value of 1.76 Hz. This coupling was also found in its corresponding multiplet partner confirming the structure:&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_-MfflvAgRls/Sijz9JEeuYI/AAAAAAAAAas/vIBenKtcMa4/s1600-h/ddd.jpeg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 279px;" src="http://1.bp.blogspot.com/_-MfflvAgRls/Sijz9JEeuYI/AAAAAAAAAas/vIBenKtcMa4/s400/ddd.jpeg" alt="" id="BLOGGER_PHOTO_ID_5343789189607373186" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;At this point, it’s worth mentioning that Resolution Booster is a very powerful method to resolve overlapped peaks, but it cannot be used for integration as the area of the peaks get distorted by this process. The good news is that we have developed a new method which in addition to taking advantage of the power of resolution booster, it yields accurate integrals.&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;This method has been named as &lt;span style="font-weight: bold; color: rgb(255, 255, 0);"&gt;Global Spectral Deconvolution&lt;/span&gt;&lt;span style="color: rgb(255, 255, 0);"&gt; (&lt;/span&gt;&lt;span style="font-weight: bold; color: rgb(255, 255, 0);"&gt;GSD&lt;/span&gt;&lt;span style="color: rgb(255, 255, 0);"&gt;)&lt;/span&gt; and as its name says, it automatically deconvolves all the peaks in a spectrum. In short, this method first recognizes all significant peaks in a spectrum, then assigns a realistic a-priori bounds to all peak parameters (chemical shift, heights, line widths, etc) and finally fits all these parameters in a very reasonable time.&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;Following with the example above, if we apply &lt;span style="font-weight: bold;"&gt;GSD&lt;/span&gt;, we get a multiplet with all the individual peaks clearly resolved and this time, with accurate integrals.&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_-MfflvAgRls/Sij0mrORFVI/AAAAAAAAAa0/Q9fZWg1R4-Q/s1600-h/GSD_ddd.jpeg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 279px;" src="http://2.bp.blogspot.com/_-MfflvAgRls/Sij0mrORFVI/AAAAAAAAAa0/Q9fZWg1R4-Q/s400/GSD_ddd.jpeg" alt="" id="BLOGGER_PHOTO_ID_5343789903149864274" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;It’s important to mention that we haven’t just fitted the multiplet above, but we have actually fitted the whole spectrum!&lt;/span&gt;&lt;/span&gt; &lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt; &lt;/span&gt;&lt;/span&gt;  &lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_-MfflvAgRls/Sij0yLnSBoI/AAAAAAAAAa8/sHfRDhPXoGM/s1600-h/GSD_Full.jpeg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 279px;" src="http://1.bp.blogspot.com/_-MfflvAgRls/Sij0yLnSBoI/AAAAAAAAAa8/sHfRDhPXoGM/s400/GSD_Full.jpeg" alt="" id="BLOGGER_PHOTO_ID_5343790100823279234" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;We are confident that GSD will open new avenues in NMR data interpretation and quantitative analysis (qNMR). I will blog about these points in future posts. &lt;/span&gt;&lt;/span&gt;  &lt;/div&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6953549091784501422-1156727111329168596?l=nmr-analysis.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/1156727111329168596/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='https://www.blogger.com/comment.g?blogID=6953549091784501422&amp;postID=1156727111329168596' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/1156727111329168596'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/1156727111329168596'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/2009/06/fighting-against-peak-overlap.html' title='Fighting against peak overlap – Introducing Global Spectral Deconvolution (GSD)'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email><gd:extendedProperty xmlns:gd='http://schemas.google.com/g/2005' name='OpenSocialUserId' value='16047913759663550274'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_-MfflvAgRls/SijyiSX2QDI/AAAAAAAAAaM/bMAXuEzjNws/s72-c/A3B2_low.jpeg' height='72' width='72'/><thr:total xmlns:thr='http://purl.org/syndication/thread/1.0'>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6953549091784501422.post-7220001328693693322</id><published>2009-05-19T04:19:00.000-07:00</published><updated>2009-05-19T09:22:25.820-07:00</updated><title type='text'>Mspin, RDC’s and efficient use of freely rotating groups</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_-MfflvAgRls/ShKZ8q7lHcI/AAAAAAAAAZU/9I126hQPTBo/s1600-h/mspin.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 289px;" src="http://4.bp.blogspot.com/_-MfflvAgRls/ShKZ8q7lHcI/AAAAAAAAAZU/9I126hQPTBo/s400/mspin.jpg" alt="" id="BLOGGER_PHOTO_ID_5337497775982845378" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;In the last ten years, &lt;span style="color: rgb(255, 204, 51);"&gt;Residual Dipolar Couplings&lt;/span&gt; (&lt;span style="color: rgb(255, 204, 102); font-weight: bold;"&gt;RDC&lt;/span&gt;) have come to occupy a very important place in the structure determination of proteins, nucleic acids and carbohydrates in liquid state. Although RDCs were originally discovered and theoretically explained for small molecules in liquid crystal solvents by A. Saupe in 1968 (&lt;a href="http://www3.interscience.wiley.com/journal/106575808/abstract"&gt;Angew. Chem. Int. Ed. Engl. 1968, 7, 97&lt;/a&gt;) the  spectra were too complex for a practical use in structure determination. The discovering of weak orienting media in water led to an explosion in the application of RDCs for biomolecule structure determination. However, those aligning media used for biomolecules were not applicable to most of the small molecules. Fortunately, recent research results considerably extended the applications of RDCs to small molecules as new  alignment media for organic solvents, either liquid crystal type as poly-?-benzyl-L-glutamate (PBLG), or mechanically stretched cross-linked polymer gels such as poly(methyl methacrylate) gel (PMMA) or polydimethylsiloxane (PDMS) are available. If you are interested in RDCs you should certainly check the very  didactic introduction in the theory by &lt;a href="http://www3.interscience.wiley.com/journal/107633228/abstract?CRETRY=1&amp;amp;SRETRY=0"&gt;Kramer et al&lt;/a&gt;. Applications and practical considerations are nicely reviewed in the recent reviews by Cristina Thiele ( See &lt;a href="http://dx.doi.org/10.1002/ejoc.200800686"&gt;this&lt;/a&gt; and &lt;a href="http://dx.doi.org/10.1002/cmr.a.20075"&gt;this&lt;/a&gt;) and Burkhard Luy ( see &lt;a href="http://dx.doi.org/10.1016/j.trac.2008.11.016"&gt;this&lt;/a&gt;).&lt;br /&gt;&lt;br /&gt;The use of RDCs in small molecule structural determination is typically based on the determination of the alignment tensor, a 3x3 matrix, which contains the information about the probability of the molecule pointing in a particular direction of the space. This matrix can be determined by least squares fitting to the experimental RDCs.&lt;br /&gt;However, there exists a further potential problem on the application of RDC to the structure determination of small molecules: &lt;span style="color: rgb(255, 255, 102);"&gt;the lack of enough independent RDCs&lt;/span&gt;, i.e, those coming from non parallel vectors,  since in most cases only 1DCH RDCs are available from F1 ( see &lt;a href="http://dx.doi.org/10.1021/jo049867w"&gt;this&lt;/a&gt;) or F2 coupled (see &lt;a href="http://dx.doi.org/10.1021/jo701871g"&gt;this&lt;/a&gt; ) HSQC type experiments, thus making the fitting problem underdetermined. Armando Navarro et al. have recently proposed an &lt;a href="http://pubs.acs.org/doi/abs/10.1021/ol8029565"&gt;elegant approach&lt;/a&gt; to get the most out of the experimental data by incorporating into the calculations two of the most common freely rotating groups, namely the methyl and phenyl groups (using 2-fold and 3-fold jump models).&lt;br /&gt;&lt;br /&gt;The authors have automated this averaging of RDCs from freely rotating groups in version 1.03 of our program &lt;span style="color: rgb(255, 255, 0); font-weight: bold;"&gt;&lt;a href="http://www.mestrelab.com/"&gt;Mspin&lt;/a&gt; &lt;/span&gt;which we hope will facilitate the use of RDC among a broader community of users interested in solving structural questions of small molecules&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6953549091784501422-7220001328693693322?l=nmr-analysis.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/7220001328693693322/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='https://www.blogger.com/comment.g?blogID=6953549091784501422&amp;postID=7220001328693693322' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/7220001328693693322'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/7220001328693693322'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/2009/05/mspin-rdcs-and-efficient-use-of-freely.html' title='Mspin, RDC’s and efficient use of freely rotating groups'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email><gd:extendedProperty xmlns:gd='http://schemas.google.com/g/2005' name='OpenSocialUserId' value='16047913759663550274'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://4.bp.blogspot.com/_-MfflvAgRls/ShKZ8q7lHcI/AAAAAAAAAZU/9I126hQPTBo/s72-c/mspin.jpg' height='72' width='72'/><thr:total xmlns:thr='http://purl.org/syndication/thread/1.0'>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6953549091784501422.post-5136808686791642139</id><published>2009-04-26T07:02:00.000-07:00</published><updated>2009-04-26T07:08:08.730-07:00</updated><title type='text'>New Mestrelab Blog</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_-MfflvAgRls/SfRp1JmSP0I/AAAAAAAAAWQ/xxPXFxdg5e0/s1600-h/mestrelab-blog.jpg"&gt;&lt;img style="margin: 0pt 10px 10px 0pt; float: left; cursor: pointer; width: 249px; height: 60px;" src="http://1.bp.blogspot.com/_-MfflvAgRls/SfRp1JmSP0I/AAAAAAAAAWQ/xxPXFxdg5e0/s400/mestrelab-blog.jpg" alt="" id="BLOGGER_PHOTO_ID_5329000620916621122" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;div  style="text-align: justify;font-family:arial;"&gt;&lt;span style="font-size:100%;"&gt;I’m happy to announce our &lt;a href="http://blog.mestrec.com/"&gt;new blog on Mestrelab&lt;/a&gt;. As Santi wrote, the purpose of this blog is &lt;span style="color: rgb(255, 204, 0);"&gt;“t&lt;/span&gt;&lt;span style="font-style: italic; color: rgb(255, 204, 0);"&gt;o report on company progress and ideas, to tell stories about our trips and conferences, and to highlight aspects of our products which we may think our users may be interested in reading, or hearing, about&lt;/span&gt;&lt;span style="color: rgb(255, 204, 0);"&gt;”&lt;/span&gt;&lt;br /&gt;A lot of people seemed to be very interested in what we're doing in &lt;a href="http://www.mestrelab.com/"&gt;Mestrelab &lt;/a&gt;so we thought that it would be helpful to create this &lt;a href="http://blog.mestrec.com/"&gt;blog &lt;/a&gt;so as to keep you all up to date on what’s going on with our commercial initiatives, trips (including photo sets from those trips) etc.&lt;br /&gt;So if you feel curious about Mestrelab activities, please visit our new &lt;a href="http://blog.mestrec.com"&gt;blog&lt;/a&gt;. We look forward to hearing from you.&lt;br /&gt;&lt;br /&gt;Mestrelab's blog: &lt;a href="http://blog.mestrec.com/"&gt;http://blog.mestrec.com&lt;/a&gt;&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6953549091784501422-5136808686791642139?l=nmr-analysis.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/5136808686791642139/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='https://www.blogger.com/comment.g?blogID=6953549091784501422&amp;postID=5136808686791642139' title='1 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/5136808686791642139'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/5136808686791642139'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/2009/04/new-mestrelab-blog.html' title='New Mestrelab Blog'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email><gd:extendedProperty xmlns:gd='http://schemas.google.com/g/2005' name='OpenSocialUserId' value='16047913759663550274'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/_-MfflvAgRls/SfRp1JmSP0I/AAAAAAAAAWQ/xxPXFxdg5e0/s72-c/mestrelab-blog.jpg' height='72' width='72'/><thr:total xmlns:thr='http://purl.org/syndication/thread/1.0'>1</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6953549091784501422.post-4437972808764901139</id><published>2009-04-21T14:16:00.001-07:00</published><updated>2009-04-21T14:24:34.747-07:00</updated><title type='text'>NMR Spectroscopy Explained</title><content type='html'>&lt;div style="text-align: justify;"&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_-MfflvAgRls/Se43vFlOcQI/AAAAAAAAAWI/QZsAw6Tc_Zk/s1600-h/NMRSpectroscopy.jpg"&gt;&lt;img style="margin: 0pt 10px 10px 0pt; float: left; cursor: pointer; width: 172px; height: 256px;" src="http://3.bp.blogspot.com/_-MfflvAgRls/Se43vFlOcQI/AAAAAAAAAWI/QZsAw6Tc_Zk/s400/NMRSpectroscopy.jpg" alt="" id="BLOGGER_PHOTO_ID_5327256691317567746" border="0" /&gt;&lt;/a&gt;When I initiated the development of MestReC back in 1995 (15 years ago!), my knowledge of NMR was fairly elementary and limited to basic theoretical rudiments (quantum mechanics description of NMR phenomenon, vector model, etc) and some experience in the practical interpretation of NMR spectra gained primarily whilst working as an organic chemist at Leicester University.&lt;br /&gt;&lt;br /&gt;That said, during that first phase of development, I wish I had enjoyed the opportunity to have access to the book ‘&lt;a href="http://www.amazon.com/NMR-Spectroscopy-Explained-Simplified-Applications/dp/0471730963"&gt;NMR Spectroscopy Explained: Simplified Theory, Applications and Examples for Organic Chemistry and Structural Biology&lt;/a&gt;' by Neil Jacobson, I’m sure that my productivity would have been boosted very significantly by it. For example, there is an unmissable section devoted to practical NMR aspects and, in particular, NMR data acquisition and processing. It’s clear from this section that the book was written from the perspective of a spectroscopist who works with NMR on a day-to-day basis (Neil Jacobsen is the &lt;a href="http://www.chem.arizona.edu/facilities/nmr/nmrindex.html"&gt;NMR Facility Manager at the University of Arizona&lt;/a&gt;). Concepts such as &lt;span style="font-weight: bold;"&gt;&lt;span style="font-style: italic;"&gt;oversampling&lt;/span&gt; &lt;/span&gt;and &lt;span style="font-weight: bold; font-style: italic;"&gt;digital filtering&lt;/span&gt; are presented in more detail than that found in standard introductory texts. I bought this book about 6 months ago and I have to say that it is a shame that it wasn’t available much earlier when I started my work on NMR.&lt;br /&gt;&lt;br /&gt;Nothing is ever perfect and if I had to point out something missing in the book it would be a chapter devoted to DOSY, which I think would make a nice addition.&lt;br /&gt;&lt;br /&gt;Overall, I believe that this is a great book which I warmly recommend to all of you who wish to deepen your understanding of NMR both from a practical and theoretical standpoint. Enjoy, and let me have your thoughts!&lt;br /&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6953549091784501422-4437972808764901139?l=nmr-analysis.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/4437972808764901139/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='https://www.blogger.com/comment.g?blogID=6953549091784501422&amp;postID=4437972808764901139' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/4437972808764901139'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/4437972808764901139'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/2009/04/nmr-spectroscopy-explained.html' title='NMR Spectroscopy Explained'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email><gd:extendedProperty xmlns:gd='http://schemas.google.com/g/2005' name='OpenSocialUserId' value='16047913759663550274'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_-MfflvAgRls/Se43vFlOcQI/AAAAAAAAAWI/QZsAw6Tc_Zk/s72-c/NMRSpectroscopy.jpg' height='72' width='72'/><thr:total xmlns:thr='http://purl.org/syndication/thread/1.0'>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6953549091784501422.post-3553563903612499163</id><published>2009-04-10T08:56:00.000-07:00</published><updated>2009-04-10T09:14:37.645-07:00</updated><title type='text'>Mnova reviewed by Tim Claridge at JCIM</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_-MfflvAgRls/Sd9tctKB_-I/AAAAAAAAAWA/atLR5klS2xU/s1600-h/NMRBookTim.gif"&gt;&lt;img style="margin: 0pt 10px 10px 0pt; float: left; cursor: pointer; width: 122px; height: 172px;" src="http://1.bp.blogspot.com/_-MfflvAgRls/Sd9tctKB_-I/AAAAAAAAAWA/atLR5klS2xU/s400/NMRBookTim.gif" alt="" id="BLOGGER_PHOTO_ID_5323093624500649954" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;a href="http://www.chem.ox.ac.uk/spectroscopy/nmr/tim/hrnmrtoc.htm"&gt;High-Resolution NMR Techniques in Organic Chemistry&lt;/a&gt; is one of the most popular books on NMR which is now used at many universities as a foundation for graduate-level courses on NMR techniques. It has been written by Tim Claridge who is the Director of NMR Spectroscopy at the Organic Chemistry Department at Oxford University and has now written a very nice &lt;a href="http://pubs.acs.org/doi/pdfplus/10.1021/ci900090d"&gt;review &lt;/a&gt;on &lt;a href="http://www.blogger.com/www.mestrelab.com"&gt;Mnova &lt;/a&gt;in the &lt;/span&gt;&lt;/span&gt;&lt;span style="font-size:100%;"&gt;&lt;a style="font-family: arial;" href="http://pubs.acs.org/journal/jcisd8"&gt;Journal of Chemistry Information and Modeling&lt;/a&gt;&lt;/span&gt;&lt;span style=";font-family:arial;font-size:100%;"  &gt; (JCIM). &lt;/span&gt;&lt;span style=";font-family:arial;font-size:100%;"  &gt;I'll just quote one of his conclusions because I'd rather let you read the full article:&lt;br /&gt;&lt;br /&gt;&lt;span style="font-style: italic; color: rgb(255, 255, 51);"&gt;Overall I was very impressed with the package, finding it not only very comfortable and intuitive to use so well suited to non-NMR specialist, but also well endowed with more advanced processing features for more experienced users&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;(Click &lt;a href="http://pubs.acs.org/doi/abs/10.1021/ci900090d"&gt;here &lt;/a&gt;for the full article)&lt;br /&gt;&lt;br /&gt;I would like to take this opportunity to &lt;/span&gt;&lt;span style=";font-family:arial;font-size:100%;"  &gt;thank all of you for your support, advice and contributions to our design and development, and also congratulate my team; it seems we are doing well at developing easy to use but powerful NMR software.&lt;/span&gt;&lt;span style=";font-family:arial;font-size:100%;"  &gt; But don’t worry, we are not going to get complacent because of reviews like this, on the contrary, they are just a spur to work harder and develop the software further&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-weight: bold;font-family:arial;font-size:100%;"  &gt;Article bookmark.&lt;/span&gt;&lt;span style="font-size:100%;"&gt; &lt;/span&gt;&lt;span style=";font-family:arial;font-size:100%;"  &gt;Tim Claridge&lt;/span&gt;&lt;span style="font-size:100%;"&gt; &lt;/span&gt;&lt;span style=";font-family:arial;font-size:100%;"  &gt;University of Oxford&lt;/span&gt;&lt;span style="font-size:100%;"&gt; &lt;/span&gt;&lt;span style=";font-family:arial;font-size:100%;"  &gt;J. Chem. Inf. Model., Article ASAP&lt;/span&gt;&lt;span style="font-size:100%;"&gt; &lt;/span&gt;&lt;span style=";font-family:arial;font-size:100%;"  &gt;DOI: 10.1021/ci900090d&lt;/span&gt;&lt;span style="font-size:100%;"&gt; &lt;/span&gt;&lt;span style=";font-family:arial;font-size:100%;"  &gt;Publication Date (Web): March 30, 2009&lt;/span&gt;&lt;span style="font-size:100%;"&gt; &lt;a style="font-family: arial;" href="http://pubs.acs.org/doi/abs/10.1021/ci900090d"&gt;http://pubs.acs.org/doi/abs/10.1021/ci900090d&lt;/a&gt; &lt;/span&gt;&lt;span style=";font-family:arial;font-size:100%;"  &gt;Copyright © 2009 American Chemical Society&lt;/span&gt;&lt;span style=";font-family:arial;font-size:100%;"  &gt;&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6953549091784501422-3553563903612499163?l=nmr-analysis.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/3553563903612499163/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='https://www.blogger.com/comment.g?blogID=6953549091784501422&amp;postID=3553563903612499163' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/3553563903612499163'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/3553563903612499163'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/2009/04/mnova-reviewed-by-tim-claridge-at-jcim_10.html' title='Mnova reviewed by Tim Claridge at JCIM'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email><gd:extendedProperty xmlns:gd='http://schemas.google.com/g/2005' name='OpenSocialUserId' value='16047913759663550274'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/_-MfflvAgRls/Sd9tctKB_-I/AAAAAAAAAWA/atLR5klS2xU/s72-c/NMRBookTim.gif' height='72' width='72'/><thr:total xmlns:thr='http://purl.org/syndication/thread/1.0'>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6953549091784501422.post-3868544445156428537</id><published>2009-03-13T10:04:00.000-07:00</published><updated>2009-03-13T12:09:36.413-07:00</updated><title type='text'>Pre-ENC User Meeting Video</title><content type='html'>As you may know, we are going to hold an user meeting prior to the &lt;a href="http://www.enc-conference.org/"&gt;50th ENC Conference&lt;/a&gt;.&lt;br /&gt;There, Mestrelab's team and some guests are going to present some new Mnova features, algorythms and new products.&lt;br /&gt;&lt;br /&gt;You can &lt;a href="http://mestrec.com/recursos.php?idr=147&amp;amp;i18n=1&amp;amp;utm_source=carlos&amp;amp;utm_medium=blogger&amp;amp;utm_campaign=conferences-enc"&gt;check the meeting program and get registered here.&lt;br /&gt;&lt;/a&gt;Whether you are planning to attend or not I also encourage you to watch this 5 minutes video.&lt;br /&gt;&lt;span style="font-size:130%;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;span style="font-weight: bold;"&gt;Double-click to switch to full screen&lt;/span&gt;&lt;br /&gt;&lt;object width="400" height="300"&gt;&lt;param name="allowfullscreen" value="true"&gt;&lt;param name="allowscriptaccess" value="always"&gt;&lt;param name="movie" value="http://vimeo.com/moogaloop.swf?clip_id=3626045&amp;amp;server=vimeo.com&amp;amp;show_title=1&amp;amp;show_byline=1&amp;amp;show_portrait=0&amp;amp;color=&amp;amp;fullscreen=1"&gt;&lt;embed src="http://vimeo.com/moogaloop.swf?clip_id=3626045&amp;amp;server=vimeo.com&amp;amp;show_title=1&amp;amp;show_byline=1&amp;amp;show_portrait=0&amp;amp;color=&amp;amp;fullscreen=1" type="application/x-shockwave-flash" allowfullscreen="true" allowscriptaccess="always" width="400" height="300"&gt;&lt;/embed&gt;&lt;/object&gt;&lt;br /&gt;&lt;a href="http://vimeo.com/3626045"&gt;Pre-ENC User Video&lt;/a&gt; from &lt;a href="http://vimeo.com/user1429788"&gt;Dani Fraga&lt;/a&gt; on &lt;a href="http://vimeo.com/"&gt;Vimeo&lt;/a&gt;.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6953549091784501422-3868544445156428537?l=nmr-analysis.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/3868544445156428537/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='https://www.blogger.com/comment.g?blogID=6953549091784501422&amp;postID=3868544445156428537' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/3868544445156428537'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/3868544445156428537'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/2009/03/pre-enc-user-meeting-video.html' title='Pre-ENC User Meeting Video'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email><gd:extendedProperty xmlns:gd='http://schemas.google.com/g/2005' name='OpenSocialUserId' value='16047913759663550274'/></author><thr:total xmlns:thr='http://purl.org/syndication/thread/1.0'>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6953549091784501422.post-469159808057123533</id><published>2009-03-05T02:46:00.000-08:00</published><updated>2009-03-05T07:21:42.616-08:00</updated><title type='text'>NMR and the Chemist’s Illusion</title><content type='html'>&lt;div style="text-align: justify;"&gt;Stan has just posted a &lt;a href="http://www.ebyte.it/stan/blog.html#09Mar02"&gt;nice entry&lt;/a&gt; in which he uses the &lt;span style="font-weight: bold;"&gt;aromatic region of Strychnine&lt;/span&gt; to discourse about the &lt;span style="font-weight: bold;"&gt;different effects in the NMR spectrum&lt;/span&gt; (in terms of resolution and multiplicity) produced when the magnetic field frequency is changed. In particular, I like his description of the &lt;span style="font-weight: bold; color: rgb(255, 255, 0);"&gt;‘Chemist’s Illusion’&lt;/span&gt; and as a chemist, I would like to illustrate, just with a picture, what this illusion is all about.&lt;br /&gt;&lt;/div&gt;&lt;div style="text-align: justify;"&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;In the picture below, I have synthesized the ABCD spin system corresponding to the aromatic region of Strychnine at different fields (we don’t own a 1500 MHz spectrometer and we don’t expect to get one for Mestrelab in the short- or mid-term :-) ). It can be appreciated that as we move to higher fields, the &lt;span style="font-weight: bold;"&gt;multiplets appear to be more separated&lt;/span&gt; (this is an illusion: their chemical shifts, in ppm,  are exactly the same!) and get more resolved and more first-order like.&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_-MfflvAgRls/Sa_LDeNv2QI/AAAAAAAAAVY/sjvX_BuK09s/s1600-h/ABCD1.jpeg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 279px;" src="http://2.bp.blogspot.com/_-MfflvAgRls/Sa_LDeNv2QI/AAAAAAAAAVY/sjvX_BuK09s/s400/ABCD1.jpeg" alt="" id="BLOGGER_PHOTO_ID_5309685746203875586" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;Below I’m showing an expansion of the right most multiplets:&lt;style&gt;&lt;br /&gt;&lt;br /&gt;itions */  @font-face  {font-family:"Cambria Math";  panose-1:2 4 5 3 5 4 6 3 2 4;  mso-font-charset:0;  mso-generic-font-family:roman;  mso-font-pitch:variable;  mso-font-signature:-1610611985 1107304683 0 0 159 0;} @font-face  {font-family:Calibri;  panose-1:2 15 5 2 2 2 4 3 2 4;  mso-font-charset:0;  mso-generic-font-family:swiss;  mso-font-pitch:variable;  mso-font-signature:-1610611985 1073750139 0 0 159 0;}  /* Style Definitions */  p.MsoNormal, li.MsoNormal, div.MsoNormal  {mso-style-unhide:no;  mso-style-qformat:yes;  mso-style-parent:"";  margin-top:0cm;  margin-right:0cm;  margin-bottom:10.0pt;  margin-left:0cm;  line-height:115%;  mso-pagination:widow-orphan;  font-size:11.0pt;  font-family:"Calibri","sans-serif";  mso-fareast-font-family:Calibri;  mso-bidi-font-family:"Times New Roman";  mso-ansi-language:ES;} .MsoChpDefault  {mso-style-type:export-only;  mso-default-props:yes;  font-size:10.0pt;  mso-ansi-font-size:10.0pt;  mso-bidi-font-size:10.0pt;  mso-ascii-font-family:Calibri;  mso-fareast-font-family:Calibri;  mso-hansi-font-family:Calibri;} @page Section1  {size:612.0pt 792.0pt;  margin:70.85pt 3.0cm 70.85pt 3.0cm;  mso-header-margin:36.0pt;  mso-footer-margin:36.0pt;  mso-paper-source:0;} div.Section1  {page:Section1;} --&gt; &lt;/style&gt;&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_-MfflvAgRls/Sa_LOOIwLzI/AAAAAAAAAVg/ESTrceo5x0Y/s1600-h/ABCD2.jpeg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 279px;" src="http://2.bp.blogspot.com/_-MfflvAgRls/Sa_LOOIwLzI/AAAAAAAAAVg/ESTrceo5x0Y/s400/ABCD2.jpeg" alt="" id="BLOGGER_PHOTO_ID_5309685930866519858" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;Another interesting and well known example is represented by an AA’BB’ spin system (for example, o-diclhrobenzene) . Again, as we go to higher fields, the apparent multiplets separation looks larger, although the multiplet fine structure remains virtually unchanged. In other words, in these systems, second order effects will always exist regardless of the magnetic field. When the magnetic field is increased, it will be possible to get a larger chemical shift difference between the AA’ and the BB’ groups, but not between A and A’ or B and B’ (it’s always zero), so that the highest simplification one can achieve by increasing the magnetic field is to move from an AA’BB’ group to an AA’XX’ group which is a second order spin system too.&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_-MfflvAgRls/Sa_LXE60FaI/AAAAAAAAAVo/U6Hp9U7v0qs/s1600-h/ODBC.jpeg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 279px;" src="http://2.bp.blogspot.com/_-MfflvAgRls/Sa_LXE60FaI/AAAAAAAAAVo/U6Hp9U7v0qs/s400/ODBC.jpeg" alt="" id="BLOGGER_PHOTO_ID_5309686083010958754" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6953549091784501422-469159808057123533?l=nmr-analysis.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/469159808057123533/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='https://www.blogger.com/comment.g?blogID=6953549091784501422&amp;postID=469159808057123533' title='4 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/469159808057123533'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/469159808057123533'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/2009/03/nmr-and-chemists-illusion.html' title='NMR and the Chemist’s Illusion'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email><gd:extendedProperty xmlns:gd='http://schemas.google.com/g/2005' name='OpenSocialUserId' value='16047913759663550274'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_-MfflvAgRls/Sa_LDeNv2QI/AAAAAAAAAVY/sjvX_BuK09s/s72-c/ABCD1.jpeg' height='72' width='72'/><thr:total xmlns:thr='http://purl.org/syndication/thread/1.0'>4</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6953549091784501422.post-166325286690549692</id><published>2009-02-23T09:59:00.000-08:00</published><updated>2009-03-02T04:10:23.047-08:00</updated><title type='text'>Peak Shapes in NMR Spectroscopy</title><content type='html'>&lt;div style="text-align: justify;"&gt;&lt;span&gt;Routine analysis of NMR data involves peak picking and integration to get chemical shifts (and couplings) and quantitative information (e.g. number of protons). When the peaks are not well resolved, none of these parameters can be accurately estimated and nonlinear least squares fit (curve fitting or deconvolution) is often performed to extract the desired information. However, deconvolution presents, at least two important difficulties:&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_-MfflvAgRls/SaLoAMehULI/AAAAAAAAAU4/SE0N7NRxqcE/s1600-h/peak_shapes.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 261px;" src="http://2.bp.blogspot.com/_-MfflvAgRls/SaLoAMehULI/AAAAAAAAAU4/SE0N7NRxqcE/s400/peak_shapes.jpg" alt="" id="BLOGGER_PHOTO_ID_5306058401042747570" border="0" /&gt;&lt;/a&gt;&lt;span style="font-weight: bold;"&gt;&lt;br /&gt;Problem #1&lt;/span&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;In general, line fitting is applied to some limited number of lines in a spectrum as a deconvolution of the full spectrum is very difficult to say the least. This implies a manual intervention of the User (choice of multiplet, specification of the number of lines and of their starting parameters).&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;span style="font-weight: bold;"&gt;Problem #2&lt;/span&gt;&lt;br /&gt;&lt;div style="text-align: justify;"&gt;Curve fitting requires the definition of an analytical model for the line shape and in particular, NMR lineshaphes have typically been assumed to be either Lorentzian, Gaussian, or a combination of both (e.g. Voight Profile). The problem is that Lorentzian deconvolutions are numerically ill defined because all complete sets of Lorentzian-shaped functions are approximately linearly dependent (in other words, a Lorentzian peak can be approximated very well by several Lorentzian lines). This problem is specially important in 1H-NMR spectra where peaks are really complicated envelopes of many unresolved transitions (for example, in a generic 10 spin system there are &lt;span style="font-style: italic;"&gt;5120 distinct main transitions&lt;/span&gt;, but one typically resolves less than &lt;span style="font-style: italic;"&gt;100 peaks&lt;/span&gt;).&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;These problems have been the motivation of the development of a brand new peak analysis algorithm, the so-called GSD (Global Spectral Deconvolution) which has been recently presented by &lt;span style="font-weight: bold;"&gt;Stan Sykora&lt;/span&gt; &lt;a href="http://www.ebyte.it/stan/Talk_MMCE_2009.html"&gt;in a talk he gave&lt;/a&gt; at &lt;a href="http://www.nmr.ki.si/mmce2009/invitation.htm"&gt;MMCE 2009 conference&lt;/a&gt;. In fact, GSD is now fully operative within &lt;a href="http://mestrec.com/index.php?idp=1&amp;amp;i18n=1"&gt;MestReNova .&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;If you are interested in GSD and planning to visit &lt;a href="http://www.enc-conference.org/"&gt;ENC&lt;/a&gt;, we will be pleased to show you every detail &lt;a href="http://mestrec.com/recursos.php?idr=147&amp;amp;i18n=1&amp;amp;utm_source=carlos&amp;amp;utm_medium=blogger&amp;amp;utm_campaign=conferences-enc"&gt;at the user meeting we will keep on Sunday 29th March&lt;/a&gt; and at our exhibitor and hospitality suite (&lt;span style="font-weight: bold; color: rgb(255, 255, 102);"&gt;you do not need to be a MestReNova User to participate&lt;/span&gt;).&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6953549091784501422-166325286690549692?l=nmr-analysis.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/166325286690549692/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='https://www.blogger.com/comment.g?blogID=6953549091784501422&amp;postID=166325286690549692' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/166325286690549692'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/166325286690549692'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/2009/02/peak-shapes-in-nmr-spectroscopy.html' title='Peak Shapes in NMR Spectroscopy'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email><gd:extendedProperty xmlns:gd='http://schemas.google.com/g/2005' name='OpenSocialUserId' value='16047913759663550274'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_-MfflvAgRls/SaLoAMehULI/AAAAAAAAAU4/SE0N7NRxqcE/s72-c/peak_shapes.jpg' height='72' width='72'/><thr:total xmlns:thr='http://purl.org/syndication/thread/1.0'>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6953549091784501422.post-7732404562985918354</id><published>2008-12-31T09:20:00.000-08:00</published><updated>2008-12-31T09:29:39.630-08:00</updated><title type='text'>DOSY-shift reagents</title><content type='html'>&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;A well-known procedure to separate resonances that would otherwise overlap in crowded NMR spectra is by adding to the sample some paramagnetic substance, the so-called shift-reagent. The most commonly used shift reagents are complexes of paramagnetic lanthanide ions such as europium(III) for down field shifts and praseodymium(III) for upfield shifts.&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;/div&gt;&lt;div style="text-align: justify;"&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;A similar approach has been recently &lt;a href="http://www3.interscience.wiley.com/journal/121515882/abstract"&gt;reported&lt;/a&gt; to resolve mixture components via &lt;a href="http://nmr-analysis.blogspot.com/2008/07/dosy-nmr.html"&gt;DOSY-NMR&lt;/a&gt;. It’s not very uncommon that in some mixture analyses, 2 or more compounds have diffusion coefficients so similar that they cannot be resolved by any mathematical procedure. For example, the figure below shows a synthetic DOSY spectrum (based on Figure 2 of the original article) of a mixture of two peptides, Trp-Gly and Leu-Met having D values nearly identical&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://3.bp.blogspot.com/_-MfflvAgRls/SVurT22KZFI/AAAAAAAAAUg/lAp0SD15JvI/s1600-h/DOSY1.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 361px;" src="http://3.bp.blogspot.com/_-MfflvAgRls/SVurT22KZFI/AAAAAAAAAUg/lAp0SD15JvI/s400/DOSY1.jpg" alt="" id="BLOGGER_PHOTO_ID_5286006945277961298" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;div style="text-align: justify;"&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;M. E. Zielinski and K. F. Morris proposed in their &lt;a href="http://www3.interscience.wiley.com/journal/121515882/abstract"&gt;article&lt;/a&gt; to add perdeuterated surfactant micelles to the mixture. Analogous to the chemical offsets induced by shift reagents, the molecules in the mixture under analysis interact differentially with the micelles and thus have different Diffusion values. &lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://1.bp.blogspot.com/_-MfflvAgRls/SVurUO7X81I/AAAAAAAAAUo/GZy7kosxFH0/s1600-h/DOSY2.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 368px;" src="http://1.bp.blogspot.com/_-MfflvAgRls/SVurUO7X81I/AAAAAAAAAUo/GZy7kosxFH0/s400/DOSY2.jpg" alt="" id="BLOGGER_PHOTO_ID_5286006951742272338" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;&lt;span style="font-size:100%;"&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;Using perdeuterated surfactant micelles to resolve mixture components in diffusion-ordered NMR spectroscopy&lt;br /&gt;Matthew E. Zielinski, Kevin F. Morris, Magnetic Resonance in Chemistry&lt;br /&gt;Volume 47 Issue 1, Pages 53 - 56&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6953549091784501422-7732404562985918354?l=nmr-analysis.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/7732404562985918354/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='https://www.blogger.com/comment.g?blogID=6953549091784501422&amp;postID=7732404562985918354' title='1 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/7732404562985918354'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/7732404562985918354'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/2008/12/dosy-shift-reagents.html' title='DOSY-shift reagents'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email><gd:extendedProperty xmlns:gd='http://schemas.google.com/g/2005' name='OpenSocialUserId' value='16047913759663550274'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_-MfflvAgRls/SVurT22KZFI/AAAAAAAAAUg/lAp0SD15JvI/s72-c/DOSY1.jpg' height='72' width='72'/><thr:total xmlns:thr='http://purl.org/syndication/thread/1.0'>1</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6953549091784501422.post-1909476419687955363</id><published>2008-12-21T14:00:00.000-08:00</published><updated>2008-12-21T14:09:25.206-08:00</updated><title type='text'>Microreview on NMR structural elucidation</title><content type='html'>&lt;div style="text-align: justify;"&gt;&lt;span style="font-family: arial;"&gt;&lt;span style="font-size:100%;"&gt;A nice short review presenting practical strategies for the elucidation of small organic molecules with NMR spectroscopy has been published a few months ago. I highly recommend it as a reference for organic chemists engaged in structural elucidation tasks.&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style="font-family: arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;span style="font-family: arial;"&gt;&lt;span style="font-size:100%;"&gt;Eugene E. Kwan, Shaw G. Huang, Structural Elucidation with NMR Spectroscopy: Practical Strategies for Organic Chemists European &lt;span style="font-style: italic;"&gt;Journal of Organic Chemistry&lt;/span&gt;, &lt;span style="font-weight: bold;"&gt;2008 &lt;/span&gt;(16), 2671-2688&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;DOI: &lt;a href="http://dx.doi.org/10.1002/ejoc.200700966" target="_blank" class="liwiley"&gt;10.1002/ejoc.200700966&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6953549091784501422-1909476419687955363?l=nmr-analysis.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://nmr-analysis.blogspot.com/feeds/1909476419687955363/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='https://www.blogger.com/comment.g?blogID=6953549091784501422&amp;postID=1909476419687955363' title='1 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/1909476419687955363'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6953549091784501422/posts/default/1909476419687955363'/><link rel='alternate' type='text/html' href='http://nmr-analysis.blogspot.com/2008/12/microreview-on-nmr-structural.html' title='Microreview on NMR structural elucidation'/><author><name>Carlos Cobas</name><uri>http://www.blogger.com/profile/13500275318435740775</uri><email>noreply@blogger.com</email><gd:extendedProperty xmlns:gd='http://schemas.google.com/g/2005' name='OpenSocialUserId' value='16047913759663550274'/></author><thr:total xmlns:thr='http://purl.org/syndication/thread/1.0'>1</thr:total></entry></feed>